文献速递放疗物理与技术泌尿生殖与妇科肿瘤放疗头颈部肿瘤放疗

新型迭代重建算法改善CBCT图像质量:一项临床评估

Improvements in CBCT Image Quality Using a Novel Iterative Reconstruction Algorithm: A Clinical Evaluation.
PubMed 文献 · Adv Radiat Oncol · 2019-01-10

本研究纳入10例前列腺癌和10例头颈癌患者,比较FDK_CBCT与新型迭代算法Iterative_CBCT的图像质量与勾画变异。Iterative_CBCT使前列腺勾画Dice系数提高约2.4%(P=.029),前列腺各区平均勾画误差降低约15%;腮腺Hausdorff距离改善约2 mm(P<.01),Dice系数提高约2%(P=.03)。观察者认为Iterative_CBCT图像均匀性、噪声水平及整体图像质量改善。

要点

  • Iterative_CBCT使前列腺勾画Dice系数提高约2.4%(P=.029),所有患者均有改善,1例提高达约10%。
  • 前列腺各区平均勾画误差降低约15%。
  • 腮腺Hausdorff距离改善约2 mm(P<.01),Dice系数提高约2%(P=.03)。

核心结论

  • 观察者注意到Iterative_CBCT数据集在图像均匀性、噪声水平和整体图像质量方面有所改善。
  • 专家观察者在前列腺和腮腺等软组织结构的勾画一致性上表现出更好的能力。
  • 该新型迭代重建算法能够改善前列腺癌和头颈癌图像引导放疗的可视化。

研究设计与样本

  • 研究纳入10例头颈癌患者和10例前列腺癌患者,对每例患者的原始CBCT采集数据分别用现有算法(FDK_CBCT)和新型迭代算法(Iterative_CBCT)重建图像。
  • 由多名放射肿瘤科医生勾画结构:前列腺癌勾画前列腺、近端2 cm精囊、膀胱和直肠;头颈癌勾画脑干、椎管、左右腮腺和左右颌下腺。
  • 采用同时真值与性能水平估计方法将观察者勾画合并为参考共识轮廓,所有观察者轮廓与参考轮廓比较,计算Dice系数、Hausdorff距离和平均轮廓距离(仅前列腺轮廓)。
  • 定性图像质量分析采用5分制量表,1分表示Iterative_CBCT图像质量明显更优,5分表示Iterative_CBCT图像质量明显更差。

主要发现

  • Iterative_CBCT数据集使前列腺勾画Dice系数提高约2.4%(P=.029)。
  • Iterative_CBCT数据集的前列腺勾画平均Dice系数在所有患者中均有改善,其中1例患者改善达约10%。
  • 平均轮廓距离结果显示,前列腺所有区域的平均勾画误差降低约15%。
  • 对于腮腺勾画,Iterative_CBCT数据集使Hausdorff距离改善约2 mm(P<.01),Dice系数提高约2%(P=.03)。
  • Iterative_CBCT数据集在97.3%(前列腺)和90.0%(头颈癌)的患者数据集中被评分为图像质量等同或更好。

临床怎么用

  • 原文结论指出,该新型迭代重建算法能够改善前列腺癌和头颈癌图像引导放疗的可视化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study aimed to evaluate the clinical utility of a novel iterative cone beam computed tomography (CBCT) reconstruction algorithm for prostate and head and neck (HN) cancer. METHODS AND MATERIALS: A total of 10 patients with HN and 10 patients with prostate cancer were analyzed. For each patient, raw CBCT acquisition data were used to reconstruct images with a currently available algorithm (FDK_CBCT) and novel iterative algorithm (Iterative_CBCT). Quantitative contouring variation analysis was performed using structures delineated by several radiation oncologists. For prostate, observers contoured the prostate, proximal 2 cm seminal vesicles, bladder, and rectum. For HN, observers contoured the brain stem, spinal canal, right-left parotid glands, and right-left submandibular glands. Observer contours were combined to form a reference consensus contour using the simultaneous truth and performance level estimation method. All observer contours then were compared with the reference contour to calculate the Dice coefficient, Hausdorff distance, and mean contour distance (prostate contour only). Qualitative image quality analysis was performed using a 5-point scale ranging from 1 (much superior image quality for Iterative_CBCT) to 5 (much inferior image quality for Iterative_CBCT). RESULTS: The Iterative_CBCT data sets resulted in a prostate contour Dice coefficient improvement of approximately 2.4% (P = .029). The average prostate contour Dice coefficient for the Iterative_CBCT data sets was improved for all patients, with improvements up to approximately 10% for 1 patient. The mean contour distance results indicate an approximate 15% reduction in mean contouring error for all prostate regions. For the parotid contours, Iterative_CBCT data sets resulted in a Hausdorff distance improvement of approximately 2 mm (P < .01) and an approximate 2% improvement in Dice coefficient (P = .03). The Iterative_CBCT data sets were scored as equivalent or of better image quality for 97.3% (prostate) and 90.0% (HN) of the patient data sets. CONCLUSIONS: Observers noted an improvement in image uniformity, noise level, and overall image quality for Iterative_CBCT data sets. In addition, expert observers displayed an improved ability to consistently delineate soft tissue structures, such as the prostate and parotid glands. Thus, the novel iterative reconstruction algorithm analyzed in this study is capable of improving the visualization for prostate and HN cancer image guided radiation therapy.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Gardner SJ, Mao W, Liu C, et al. Improvements in CBCT Image Quality Using a Novel Iterative Reconstruction Algorithm: A Clinical Evaluation. Adv Radiat Oncol. 2019. PMID: 31011685. doi:10.1016/j.adro.2018.12.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。