DCE与DSC灌注MRI在射波刀放射外科治疗的原发与转移性轴内脑肿瘤随访中的诊断准确性
研究纳入72个强化病灶(57个脑转移瘤、15个原发脑肿瘤),比较DCE与DSC灌注MRI在射波刀立体定向放射外科后鉴别放射性坏死与肿瘤复发的诊断准确性。Ktrans与诊断相关(rpb=0.54,p<0.001),rCBV亦相关(rpb=0.37,p=0.002)。Ktrans最佳截断值28.76(敏感度0.89、特异度0.97),rCBV最佳截断值1.23(敏感度0.88、特异度0.75)。
要点
- Ktrans与放射性坏死或肿瘤复发的诊断相关(rpb=0.54,p<0.001)。
- rCBV与诊断相关(rpb=0.37,p=0.002)。
- Ktrans截断值28.76时敏感度0.89、特异度0.97。
核心结论
- MRI灌注技术,尤其是DCE,有助于在放射外科术后随访中鉴别肿瘤复发与放射性坏死。
研究设计与样本
- 根据临床影像学标准判定肿瘤复发或放射性坏死,分别用点二列相关系数评估其与rCBV和Ktrans的统计关系。
主要发现
- 放射性坏死或复发肿瘤的诊断与Ktrans相关(rpb=0.54,p<0.001)。
- 放射性坏死或复发肿瘤的诊断与rCBV相关(rpb=0.37,p=0.002)。
- rCBV的ROC分析显示良好的分类能力,最佳截断值k=1.23,敏感度0.88、特异度0.75。
- Ktrans的ROC分析显示良好的分类能力,最佳截断值k=28.76,敏感度0.89、特异度0.97。
关键数值与推荐
- rCBV最佳截断值k=1.23,敏感度0.88、特异度0.75。
- Ktrans最佳截断值k=28.76,敏感度0.89、特异度0.97。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The differential diagnosis between radiation necrosis, tumor recurrence and tumor progression is crucial for the evaluation of treatment response and treatment planning. The appearance of treatment-induced tissue necrosis on conventional Magnetic Resonance Imaging (MRI) is similar to brain tumor recurrence and it could be difficult to differentiate the two entities on follow-up MRI examinations. Dynamic Susceptibility Contrast-enhanced (DSC) and Dynamic Contrast-Enhanced (DCE) are MRI perfusion techniques that use an exogenous, intravascular, non-diffusible gadolinium-based contrast agent. The aim of this study was to compare the diagnostic accuracy of DSC and DCE perfusion MRI in the differential diagnosis between radiation necrosis and tumor recurrence, in the follow-up of primary and metastatic intra-axial brain tumors after Stereotactic RadioSurgery (SRS) performed with CyberKnife. METHODS: A total of 72 enhancing lesions (57 brain metastases and 15 primary brain tumors) were analyzed with DCE and DSC, by means of MRI acquisition performed by 1,5 Tesla MR scanner. The statistical relationship between the diagnosis of tumor recurrence or radiation necrosis, decided according to clinicoradiologically criteria, rCBV and Ktrans was evaluated by the point-biserial correlation coefficient respectively. RESULTS: The statistical analysis showed a correlation between the diagnosis of radiation necrosis or recurrent tumor with Ktrans (rpb = 0.54, p < 0.001) and with rCBV (rpb = 0.37, p = 0.002). The ROC analysis of rCBV values demonstrated a good classification ability in differentiating radiation necrosis from tumour recurrence as well as the Ktrans. The optimal cut-off value for rCBV was k = 1.23 with 0.88 of sensitivity and 0.75 of specificity while for Ktrans was k = 28.76 with 0.89 of sensitivity and 0.97 of specificity. CONCLUSIONS: MRI perfusion techniques, particularly DCE, help in the differential diagnosis by tumor recurrence and radiation necrosis during the follow-up after radiosurgery.
引用
- Morabito R, Alafaci C, Pergolizzi S, et al. DCE and DSC perfusion MRI diagnostic accuracy in the follow-up of primary and metastatic intra-axial brain tumors treated by radiosurgery with cyberknife. Radiat Oncol. 2019. PMID: 30992043. doi:10.1186/s13014-019-1271-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。