文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

前瞻性研究量化宫颈癌盆腔调强放疗同步推量时受累盆腔淋巴结的外扩范围

Prospective Study to Quantify Expansion Volumes Around the Involved Pelvic Lymph Nodes to Plan Simultaneous Integrated Boost in Patients With Cervical Cancer Undergoing Pelvic Intensity Modulated Radiation Therapy.
PubMed 文献 · Pract Radiat Oncol · 2019-02-22

该前瞻性研究对19例宫颈癌患者的32枚氟脱氧葡萄糖高摄取盆腔淋巴结行四维计算机断层扫描,在不同呼吸时相勾画以计算呼吸位移,并通过每日治疗时的机载影像估计摆位误差。采用McKenzie与Van Herk公式分别量化外扩边界,结果显示内靶区需3 mm、计划靶区需5 mm的各向同性外扩,而Van Herk公式所需单一6 mm外扩虽显著缩小推量体积,但方法学固有局限可能增加靶区漏照风险。

要点

  • 基于McKenzie公式,内靶区需3 mm、计划靶区需5 mm外扩以分别涵盖呼吸与摆位不确定度。
  • 采用Van Herk公式需对所有不确定度采用单一6 mm外扩,推量体积显著缩小。
  • 作者指出方法学固有局限可能使较小外扩边界的靶区漏照风险升高。

核心结论

  • 宫颈癌盆腔调强放疗同步推量时,肿大盆腔淋巴结需内靶区3 mm、计划靶区5 mm的各向同性外扩边界。

研究设计与样本

  • 前瞻性研究纳入19例宫颈癌患者,对32枚氟脱氧葡萄糖高摄取盆腔淋巴结行四维计算机断层扫描并在不同呼吸时相勾画以计算呼吸位移。
  • 通过每日治疗时的机载影像估计摆位变异,分别采用McKenzie与Van Herk公式量化外扩边界,并用方差分析评估边界的体积影响。

主要发现

  • 基于McKenzie公式,内靶区(内靶体积)需3 mm、计划靶区需5 mm以分别充分涵盖呼吸与摆位不确定度。
  • 采用Van Herk公式需对所有不确定度采用单一6 mm外扩边界,推量体积显著缩小。
  • 作者指出其方法学固有局限可能使较小外扩边界带来更高的靶区漏照风险。

关键数值与推荐

  • McKenzie公式:内靶区外扩3 mm,计划靶区外扩5 mm。
  • Van Herk公式:对所有不确定度采用单一6 mm外扩边界。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 作者指出其方法学存在固有局限,采用较小外扩边界时可能带来更高的靶区漏照风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study aimed to calculate the expansion margins around enlarged pelvic lymph nodes to encompass internal motion and setup errors during intensity modulated radiation therapy with simultaneous integrated boost for cervical cancer. METHODS AND MATERIALS: Four-dimensional computed tomography scans were obtained for 19 patients with cervical cancer, and 32 fluorodeoxyglucose-avid pelvic lymph nodes were delineated in different respiratory phases to calculate respiratory displacement. Setup variations during daily treatments were estimated from on-board imaging. Descriptive statistics were used to quantify the expansion margins using Mc Kenzie and Van Herk formulas separately. An analysis of variance was used to analyze the volumetric impact of the margins. RESULTS: Based on the McKenzie formula, an internal margin (internal target volume) of 3 mm and setup margin (planning target volume) of 5 mm was required to adequately encompass respiratory and setup uncertainties, respectively. Although the use of the Van Herk formula necessitated a single 6 mm expansion margin for all uncertainties, which resulted in a significant reduction in boost volume, inherent limitations in our methodology might pose a higher risk of target miss with such smaller margins. CONCLUSIONS: An isotropic expansion margin of 3 mm for the internal target volume and 5 mm for the planning target volume is necessary for enlarged pelvic lymph nodes while planning intensity modulated radiation therapy with simultaneous integrated boost for cervical cancer.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Miriyala R, Rai B, Ballari NR, et al. Prospective Study to Quantify Expansion Volumes Around the Involved Pelvic Lymph Nodes to Plan Simultaneous Integrated Boost in Patients With Cervical Cancer Undergoing Pelvic Intensity Modulated Radiation Therapy. Pract Radiat Oncol. 2019. PMID: 30802616. doi:10.1016/j.prro.2019.02.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。