剂量递增前列腺癌放疗中剂量投照技术改进与PTV外扩缩减的互补关系
本研究对10例前列腺癌患者基于两种PTV外扩方案(10/8 mm和6/5 mm)与两种处方剂量(70 Gy和78 Gy)生成三维适形放疗和IMRT计划,用Lyman-Kutcher-Burman模型计算8种情景下直肠和膀胱晚期毒性NTCP。结果显示仅实施IMRT可使直肠NTCP较三维适形放疗降低2.1%至7.3%,而IMRT联合PTV外扩缩减是剂量从70 Gy递增至78 Gy时直肠NTCP保持<5%所必需的。
要点
- 仅实施IMRT技术可使直肠NTCP较三维适形放疗降低2.1%至7.3%。
- 处方总剂量从70 Gy改为78 Gy且投照与图像引导技术不变时,直肠NTCP增加3.5至4.1倍。
- IMRT联合PTV外扩缩减是剂量从70 Gy递增至78 Gy时直肠NTCP保持<5%所必需的。
核心结论
- IMRT引入与PTV外扩缩减之间的互补关系得到证实,两者均需实施才能在前列腺癌剂量递增放疗中安全给予根治剂量。
研究设计与样本
- 对10例前列腺癌患者基于两种PTV外扩方案(10/8 mm和6/5 mm)与两种处方剂量(70 Gy和78 Gy)生成三维适形放疗和IMRT计划,共8种情景,用Lyman-Kutcher-Burman模型计算直肠和膀胱晚期毒性NTCP,并计算PTV的适形性和均匀性指数。
主要发现
- IMRT计划在适形性上优于三维适形放疗计划,在均匀性上劣于三维适形放疗计划。
- 处方总剂量从70 Gy改为78 Gy且剂量投照与图像引导放疗技术不变时,直肠NTCP增加3.5至4.1倍。
- PTV外扩缩减可显著降低直肠NTCP值。
- 仅实施IMRT技术可使直肠NTCP值较三维适形放疗降低2.1%至7.3%。
- IMRT联合PTV外扩缩减是剂量从70 Gy递增至78 Gy时直肠NTCP保持<5%所必需的。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The purpose of this study is to demonstrate quantitatively the complementary relationship between the introduction of intensity modulated radiation therapy (IMRT) and planning target volume (PTV) margin reduction with an image guided technique in reducing the risk of rectal toxicity in dose-escalating prostate radiation therapy. METHODS AND MATERIALS: Three-dimensional conformal radiation therapy (CRT) and IMRT plans were generated for 10 patients with prostate cancer based on 2 PTV margin protocols (10/8 mm and 6/5 mm) and 2 dose prescriptions (70 Gy and 78 Gy). The normal tissue complication probability (NTCP) for each of the 8 scenarios was calculated using the Lyman-Kutcher-Burman model to estimate the risk of rectal and bladder late toxicity. The conformity and homogeneity indices of PTVs were calculated for each plan. RESULTS: The IMRT plans showed superiority in conformity and inferiority in homogeneity over 3-dimensional CRT plans. The rectal NTCPs were increased 3.5 to 4.1 times when the prescribed total dose was changed from 70 Gy to 78 Gy and the dose delivery and the image guided radiation therapy techniques remained unchanged. PTV margin reduction was shown to reduce the value of rectal NTCP significantly. Overall, implementing the IMRT technique alone could reduce the NTCP values only by 2.1% to 7.3% from those of 3-dimensional CRT. The introduction of both IMRT and PTV margin reduction was found to be necessary for rectal NTCP to remain <5% in the dose escalation from 70 to 78 Gy. CONCLUSIONS: The complementary relationship between the introduction of IMRT and PTV margin reduction was proven. We found that both approaches need to be implemented to safely deliver a curative dose in dose-escalating prostate radiation therapy.
引用
- Utsunomiya S, Yamamoto J, Tanabe S, et al. Complementary Relation Between the Improvement of Dose Delivery Technique and PTV Margin Reduction in Dose-Escalated Radiation Therapy for Prostate Cancer. Pract Radiat Oncol. 2019. PMID: 30772440. doi:10.1016/j.prro.2019.02.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。