功能性与解剖学剂量学参数对局部晚期非小细胞肺癌放射性肺损伤预测能力的比较
本研究纳入42例接受放疗的III期非小细胞肺癌患者,比较基于灌注SPECT的剂量-功能直方图(DFH)与基于模拟CT的剂量-体积直方图(DVH)对≥2级放射性肺损伤(RILT)的预测价值。结果显示,治疗中期DFH参数的AUC范围0.767-0.891,高于解剖学参数,但差异未达统计学显著。
要点
- 42例III期NSCLC患者中≥2级RILT累积发生率为31%。
- 功能指标FV5-FV20及FMLD在有无≥2级RILT患者间差异显著(p<0.05)。
- 治疗中期DFH的AUC范围0.767-0.891,预测准确性似乎优于解剖学参数,但差异未达统计学显著。
核心结论
- 在本研究人群中,基于Q-SPECT的治疗中期DFH参数在≥2级RILT患者中显著升高。
- 在比较的各项指标中,治疗中期DFH似乎具有更好的预测准确性,但该差异未达统计学显著。
研究设计与样本
- 研究人群为接受放疗并参加前瞻性影像学研究的NSCLC患者,仅纳入III期且治疗中期扫描可见功能性肺(FL)变化的患者。
- 在放疗前及放疗期间(约40-45 Gy)行Q-SPECT,计算基于模拟CT的基线及治疗中期DVH,以及基于Q-SPECT的基线及治疗中期DFH。
- RILT按已报道的量表进行分级。
主要发现
- 42例III期NSCLC患者符合纳入标准,≥2级RILT累积发生率为31%。
- 有无≥2级RILT患者间,功能指标如5 Gy递增的FV5-FV20及FMLD差异显著(p<0.05)。
- 解剖学指标V5-V20及MLD也获得相似结果(p<0.05)。
- 基线DVH参数的AUC范围为0.724-0.812,治疗中期DVH为0.745-0.830,基线DFH为0.764-0.878,治疗中期DFH为0.767-0.891。
- 主成分分析显示,基线/治疗中期DVH的AUC分别为0.814/0.817,基线/治疗中期DFH的AUC分别为0.790/0.857。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate the predictive value of the perfusion (Q) single-photon emission computed tomography (SPECT)-weighted dose-function histogram (DFH) obtained mid-treatment (mid-Tx) with radiotherapy (RT) for radiation-induced lung toxicity (RILT) in patients with non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: The study population consisted of NSCLC patients who were undergoing RT treatment and enrolled in prospective imaging studies. Q-SPECT was performed prior to and during RT (at ∼40-45 Gy). A baseline dose-volume histogram (DVH) and mid-Tx DVH based on simulation CT as well as a baseline DFH and mid-Tx DFH based on Q-SPECT were calculated. Only patients with stage III NSCLC and visible functional lung (FL) changes on the mid-Tx scan were eligible for this enriched analysis. RILT was graded according to a reported scale. RESULTS: Forty-two stage III NSCLC patients met the criteria for inclusion. The accumulative incidence of grade ≥2 RILT was 31% in this high-risk population. Significant differences in functional metrics such as functional lung volume FV5-FV20 at increments of 5 Gy and functional MLD (FMLD) were observed between patients with and without grade ≥2 RILT (p < 0.05). Similar results were also obtained for anatomical metrics from V5-V20 and MLD (p < 0.05). The areas under the receiver operating characteristic curves (AUCs) ranged from 0.724to 0.812 for baseline DVH parameters, from 0.745 to 0.830 for mid-Tx DVH parameters, from 0.764 to 0.878 for baseline DFH parameters, and from 0.767 to 0.891 for mid-Tx DFH parameters. Further principal components analysis showed that the AUCs were 0.814/0.817 and 0.790/0.857 for baseline/mid-Tx DVH and baseline/mid-Tx DFH, respectively. CONCLUSIONS: Mid-Tx DFH parameters based on Q-SPECT were significantly elevated in patients with grade ≥2 RILT in this study population. Among the metrics compared, mid-Tx DFH seemed to have better predictive accuracy, but this difference did not reach statistical difference.
引用
- Xiao L, Yang G, Chen J, et al. Comparison of predictive powers of functional and anatomic dosimetric parameters for radiation-induced lung toxicity in locally advanced non-small cell lung cancer. Radiother Oncol. 2018. PMID: 30471708. doi:10.1016/j.radonc.2018.09.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。