碳标记影像引导提高乳腺癌保乳术后瘤床定位在放射治疗中的准确性
本研究探讨使用碳标记结合二维千伏影像定位早期乳腺癌保乳术后瘤床的可行性与准确性。碳标记匹配的摆位误差最小,计划靶区外扩边界为3.5 mm,小于皮肤标记的12 mm、骨性匹配的9.2 mm和全乳锥形束CT匹配的6.5 mm。
要点
- 碳标记在二维千伏影像上可见性充分,伪影极小。
- 碳标记匹配的计划靶区外扩边界为3.5 mm,为4种摆位方法中最小。
- 与自由呼吸相比,深吸气屏气总体降低摆位误差标准差,但需进一步研究。
核心结论
- 碳标记匹配提高了瘤床定位准确性,减少残余摆位误差和计划靶区外扩边界,有利于保护正常组织而不降低疗效。
研究设计与样本
- 术中在瘤床周边放置碳标记;9例接受全乳放疗加瘤床补量,2例接受三维适形部分乳腺照射,共评估89个分次。
- 以锥形束CT匹配瘤床为预设金标准,比较4种摆位方法的摆位误差:激光对准皮肤标记、二维千伏机载影像骨性匹配、锥形束CT全乳匹配、二维千伏机载影像碳标记匹配。
- 计划靶区外扩边界按摆位误差的2个标准差计算,并在4种摆位方法间比较;另比较自由呼吸与深吸气屏气患者的摆位误差。
主要发现
- 碳标记在机载影像上可见性充分,伪影极小。
- 4种对准方法中,二维千伏机载影像碳标记匹配的摆位误差最小。
- 计划靶区外扩边界:激光对准皮肤标记12 mm,机载影像骨性匹配9.2 mm,锥形束CT全乳匹配6.5 mm,二维千伏机载影像碳标记匹配3.5 mm。
- 与自由呼吸相比,深吸气屏气总体降低摆位误差的标准差,但需进一步研究。
关键数值与推荐
- 计划靶区外扩边界按摆位误差的2个标准差计算。
- 以锥形束CT匹配瘤床作为预设金标准评估摆位误差。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文在深吸气屏气与自由呼吸比较处写明需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We investigated the feasibility and accuracy of using carbon fiducials to localize the lumpectomy cavity with 2-dimensional kV imaging for early stage breast cancer radiation therapy. METHODS AND MATERIALS: Carbon fiducials were placed intraoperatively in the periphery of the lumpectomy cavity. Nine patients received whole breast irradiation with a boost, and 2 patients received 3-dimensional conformal partial breast irradiation. A total of 89 fractions were assessed for setup errors relative to a predefined gold standard, cone beam computed tomography (CBCT) match to the lumpectomy cavity, using the following 4 setup methods: (1) Align skin tattoos with lasers; (2) match bone with 2-dimensional-2-dimensional (2D/2D) kV onboard imaging (OBI); (3) match the whole breast with CBCT; and (4) match carbon fiducials with 2D/2D kV OBI. The margin for the planning target volume (PTV) was calculated by 2 standard deviations of the setup errors, and compared among the 4 setup methods. Setup errors for patients treated with free breathing and patients with deep inspiration breath hold were also compared. RESULTS: The carbon fiducials were sufficiently visible on OBI for matching and introduced minimal artifacts. Of the 4 alignment methods, 2D/2D OBI match to fiducials resulted in the smallest setup errors. The PTV margin was 12 mm for aligning skin tattoos using lasers, 9.2 mm for matching bone on OBI, 6.5 mm for matching breast on CBCT, and 3.5 mm for matching fiducials on 2D/2D OBI. Compared with free breathing, deep inspiration breath hold generally reduced the standard deviations of the setup errors, but further investigation would be needed. CONCLUSIONS: Matching to carbon fiducials increased the localization accuracy to the lumpectomy cavity. This reduces residual setup error and PTV margins, facilitating tissue sparing without diminishing treatment efficacy.
引用
- Zhang Y, Mutter RW, Park SS, et al. Carbon Fiducial Image Guidance Increases the Accuracy of Lumpectomy Cavity Localization in Radiation Therapy for Breast Cancer. Pract Radiat Oncol. 2018. PMID: 30287358. doi:10.1016/j.prro.2018.09.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。