文献速递胸部肿瘤放疗放疗物理与技术

接受放疗的肺癌患者中,CT 肺通气替代指标与超极化氦-3 及氙-129 气体 MRI 的空间比较

Spatial Comparison of CT-Based Surrogates of Lung Ventilation With Hyperpolarized Helium-3 and Xenon-129 Gas MRI in Patients Undergoing Radiation Therapy.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2018-05-10

11 例肺癌患者接受氙-129 与氦-3 通气 MRI 及同呼吸质子解剖 MRI,并计算 3 种 CT 通气指标(CTHU、CTJac、CTSGV),在体素及 5×5 至 20×20 感兴趣区水平与气体 MRI 做空间相关分析;CT 通气与气体 MRI 的相关随感兴趣区增大而升高,CTHU 相关强于 CTJac 与 CTSGV,但均低于氦-3 与氙-129 MRI 之间的相关(P < .05)。

要点

  • 11 例肺癌患者中,CT 通气指标与超极化气体 MRI 的空间相关随感兴趣区增大而升高。
  • CTHU 与氦-3/氙-129 MRI 的相关强于 CTJac 与 CTSGV。
  • 氦-3 与氙-129 MRI 之间的相关始终高于任一气体与 CT 通气图的相关(P < .05)。

核心结论

  • 使用专用采集与分析方案,CT 与配准的超极化气体 MRI 的通气相关指标可在体素水平进行比较。
  • CT 通气与 MRI 在区域水平存在中等程度相关。
  • MRI 与 CT 之间的相关显著低于氦-3 与氙-129 MRI 之间的相关,提示 CT 通气替代指标可能并非仅测量肺通气。

研究设计与样本

  • 11 例肺癌患者接受氙-129 与氦-3 通气 MRI 及配准的质子解剖 MRI。
  • 采用呼气相与吸气相屏气 CT 进行形变配准并计算 3 种 CT 通气指标:CTHU、CTJac 与 CTSGV。
  • 吸气相 CT 与超极化气体通气 MRI 经同呼吸质子 MRI 配准。
  • 在体素水平及 5×5、10×10、15×15、20×20 感兴趣区内计算 CT 通气图与对应氦-3/氙-129 MRI 的 Spearman 相关系数。
  • 同时评估氦-3 与氙-129 MRI 之间的相关。

主要发现

  • CT 通气与氦-3/氙-129 MRI 的空间相关随感兴趣区增大而升高。
  • 以 CTHU 为例,体素水平平均±标准差 Spearman 系数分别为 0.37±0.19/0.33±0.17,20×20 感兴趣区分别为 0.52±0.20/0.51±0.18。
  • CTHU 的相关强于 CTJac 或 CTSGV。
  • 在所有感兴趣区,氦-3 与氙-129 MRI 之间的相关始终高于任一气体与 CT 通气图之间的相关(P < .05)。
  • CT 通气与氦-3 MRI 之间、CT 通气与氙-129 MRI 之间未见显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To develop and apply an image acquisition and analysis strategy for spatial comparison of computed tomography (CT)-ventilation images with hyperpolarized gas magnetic resonance imaging (MRI). METHODS AND MATERIALS: Eleven lung cancer patients underwent xenon-129 (129Xe) and helium-3 (3He) ventilation MRI and coregistered proton (1H) anatomic MRI. Expiratory and inspiratory breath-hold CTs were used for deformable image registration and calculation of 3 CT-ventilation metrics: Hounsfield unit (CTHU), Jacobian (CTJac), and specific gas volume change (CTSGV). Inspiration CT and hyperpolarized gas ventilation MRI were registered via same-breath anatomic 1H-MRI. Voxel-wise Spearman correlation coefficients were calculated between each CT-ventilation image and its corresponding 3He-/129Xe-MRI, and for the mean values in regions of interest (ROIs) ranging from fine to coarse in-plane dimensions of 5 × 5, 10 × 10, 15 × 15, and 20 × 20, located within the lungs as defined by the same-breath 1H-MRI lung mask. Correlation of 3He and 129Xe-MRI was also assessed. RESULTS: Spatial correlation of CT-ventilation against 3He/129Xe-MRI increased with ROI size. For example, for CTHU, mean ± SD Spearman coefficients were 0.37 ± 0.19/0.33 ± 0.17 at the voxel-level and 0.52 ± 0.20/0.51 ± 0.18 for 20 × 20 ROIs, respectively. Correlations were stronger for CTHU than for CTJac or CTSGV. Correlation of 3He with 129Xe-MRI was consistently higher than either gas against CT-ventilation maps over all ROIs (P < .05). No significant differences were observed between CT-ventilation versus 3He-MRI and CT-ventilation versus 129Xe-MRI. CONCLUSION: Comparison of ventilation-related measures from CT and registered hyperpolarized gas MRI is feasible at a voxel level using a dedicated acquisition and analysis protocol. Moderate correlation between CT-ventilation and MRI exists at a regional level. Correlation between MRI and CT is significantly less than that between 3He and 129Xe-MRI, suggesting that CT-ventilation surrogate measures may not be measuring lung ventilation alone.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Tahir BA, Hughes PJC, Robinson SD, et al. Spatial Comparison of CT-Based Surrogates of Lung Ventilation With Hyperpolarized Helium-3 and Xenon-129 Gas MRI in Patients Undergoing Radiation Therapy. Int J Radiat Oncol Biol Phys. 2018. PMID: 30355463. doi:10.1016/j.ijrobp.2018.04.077

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。