建模患者特异性剂量-功能反应以增强个体化功能损伤表征
本研究回顾性分析了非小细胞肺癌患者放疗期间的灌注SPECT/CT影像,对每例患者的剂量-功能反应应用患者特异性逻辑模型,并汇总为群体水平剂量-功能反应模型。结果显示放疗后肺功能纵向显著下降,基线功能较高的体素损伤率高于功能较低的体素。
要点
- 对非小细胞肺癌患者放疗的剂量-功能反应进行患者特异性建模,并生成群体水平模型。
- 放疗后观察到肺功能纵向显著下降,基于归一化灌注强度的体素变化分析。
- 基线功能较高的体素损伤率高于功能较低的体素。
核心结论
- 本研究对非小细胞肺癌患者放疗期间及之后的患者特异性剂量-功能反应进行了建模。
- 生成的群体水平剂量-功能反应模型源自个体患者评估,有望为功能引导的治疗计划提供预期功能性肺损伤信息。
研究设计与样本
- 回顾性分析,获取基线(n=81)、治疗中(n=74)、治疗后3个月(n=51)和治疗后1年(n=26)的灌注单光子发射计算机断层扫描/计算机断层扫描图像。
- 患者接受常规分割放疗或立体定向体部放疗,以归一化灌注单光子发射计算机断层扫描体素强度作为局部肺功能的替代指标。
- 对每例患者的剂量-功能反应应用患者特异性逻辑模型,并平均患者特异性模型参数以创建群体水平逻辑剂量-反应模型。
主要发现
- 通过分析归一化灌注强度的体素变化,观察到放疗后肺功能纵向显著下降。
- 生成的剂量-功能反应模型代表未知患者接受常规分割放疗或立体定向体部放疗时预期的体素功能下降及相关不确定性。
- 基于体素基线功能状态的治疗反应差异表明,初始功能较高的体素损伤率高于功能较低的体素。
局限性
- 本研究为回顾性分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Functional-guided radiation therapy (RT) plans have the potential to limit damage to normal tissue and reduce toxicity. Although functional imaging modalities have continued to improve, a limited understanding of the functional response to radiation and its application to personalized therapy has hindered clinical implementation. The purpose of this study was to retrospectively model the longitudinal, patient-specific dose-function response in non-small cell lung cancer patients treated with RT to better characterize the expected functional damage in future, unknown patients. METHODS AND MATERIALS: Perfusion single-photon emission computed tomography/computed tomography scans were obtained at baseline (n = 81), midtreatment (n = 74), 3 months post-treatment (n = 51), and 1 year post-treatment (n = 26) and retrospectively analyzed. Patients were treated with conventionally fractionated RT or stereotactic body RT. Normalized perfusion single-photon emission computed tomography voxel intensity was used as a surrogate for local lung function. A patient-specific logistic model was applied to each individual patient's dose-function response to characterize functional reduction at each imaging time point. Patient-specific model parameters were averaged to create a population-level logistic dose-response model. RESULTS: A significant longitudinal decrease in lung function was observed after RT by analyzing the voxelwise change in normalized perfusion intensity. Generated dose-function response models represent the expected voxelwise reduction in function, and the associated uncertainty, for an unknown patient receiving conventionally fractionated RT or stereotactic body RT. Differential treatment responses based on the functional status of the voxel at baseline suggest that initially higher functioning voxels are damaged at a higher rate than lower functioning voxels. CONCLUSIONS: This study modeled the patient-specific dose-function response in patients with non-small cell lung cancer during and after radiation treatment. The generated population-level dose-function response models were derived from individual patient assessment and have the potential to inform functional-guided treatment plans regarding the expected functional lung damage. This type of patient-specific modeling approach can be applied broadly to other functional response analyses to better capture intrapatient dependencies and characterize personalized functional damage.
引用
- Owen DR, Boonstra PS, Viglianti BL, et al. Modeling Patient-Specific Dose-Function Response for Enhanced Characterization of Personalized Functional Damage. Int J Radiat Oncol Biol Phys. 2018. PMID: 30108006. doi:10.1016/j.ijrobp.2018.05.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。