早期非小细胞肺癌单次碳离子放射治疗的肿瘤控制概率分析
该研究基于394例早期非小细胞肺癌患者的已发表临床数据开展Meta分析,用线性二次(LQ)模型和通用生存曲线(USC)模型拟合不同分次方案的3年局部控制数据。USC模型对单次照射的局部控制率估计优于LQ模型,据此创建的USC优化SOBP设计较传统SOBP具有更平坦的RBE分布,并给出更好的临床剂量预测。
要点
- USC模型对单次碳离子放疗的3年局部控制数据拟合优于LQ模型。
- 不同SOBP尺寸拟合得到转换剂量为5.6至7.0 Gy。
- LQ模型α/β比在7.4至9.1 Gy之间,USC模型在7.4至9.4 Gy之间。
核心结论
- USC模型对单次碳离子放疗的局部控制率提供了更好的估计。
- 对于分次更多的方案,LQ与USC模型的局部控制率估计相当。
- 据此创建了基于USC的单次照射SOBP设计,该设计较传统SOBP具有更平坦的RBE分布,并给出更好的临床剂量预测以优化肿瘤控制率。
研究设计与样本
- 对394例早期非小细胞肺癌患者的已发表临床数据进行Meta分析。
- 基于LQ和USC模型,同时拟合不同分次方案的临床数据并考虑若干SOBP尺寸,进行肿瘤控制概率建模。
- 碳离子放疗方案包括:总剂量59.4至95.4 Gy(RBE)分18次,72 Gy(RBE)分9次,52.8至60 Gy(RBE)分4次,28至50 Gy(RBE)单次。
主要发现
- USC模型对3年局部控制数据的拟合优于LQ模型。
- 使用不同SOBP尺寸拟合得到的转换剂量在5.6至7.0 Gy之间。
- LQ模型的α/β比在7.4至9.1 Gy之间,USC模型的α/β比在7.4至9.4 Gy之间。
- USC优化SOBP设计较传统SOBP设计具有更平坦的RBE分布。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate the suitability of the linear-quadratic (LQ) and universal survival curve (USC) models in describing the 3-year tumor control probability data of patients with stage I non-small cell lung cancer treated with carbon-ion radiation therapy. Carbon-ion radiation therapy was given at a total dose of 59.4 to 95.4 Gy (relative biological effectiveness [RBE]) in 18 fractions, at 72 Gy[RBE] in 9 fractions, at 52.8 to 60 Gy[RBE] in 4 fractions, and at 28 to 50 Gy[RBE] in a single fraction. METHODS AND MATERIALS: A meta-analysis of published clinical data from 394 patients presenting with early-stage non-small cell lung cancer was conducted. Tumor control probability modeling based on the LQ and USC models was performed by simultaneously fitting the clinical data obtained from the different fractionation schedules while considering several spread-out Bragg peak (SOBP) sizes. Radiobiological parameters were derived from the fit. On the basis of the results, a novel SOBP was created for the single-fraction regimen that was optimized with respect to the USC model and aimed at achieving a 95% local control. RESULTS: The USC model gave a better fit to the 3-year local control data than the LQ model did. The fit using various SOBP sizes yielded transition doses between 5.6 and 7.0 Gy. The results also revealed α/β ratios between 7.4 and 9.1 Gy for the LQ model and between 7.4 and 9.4 Gy for the USC model. CONCLUSIONS: The USC model provided a better estimate of the local control rate for the single-fraction course. For the schemes with a greater number of fractions, the local control rate estimates from the LQ and USC models were comparable. A USC-based SOBP design was then created for the single-fraction schedule. The updated design resulted in a flatter RBE profile compared with the conventional SOBP design. It also gave a better clinical dose prediction to optimize the tumor control rate.
引用
- Paz AE, Yamamoto N, Sakama M, et al. Tumor Control Probability Analysis for Single-Fraction Carbon-Ion Radiation Therapy of Early-Stage Non-small Cell Lung Cancer. Int J Radiat Oncol Biol Phys. 2018. PMID: 30076985. doi:10.1016/j.ijrobp.2018.07.2009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。