肿瘤与颈段脊髓标准化摄取比(SUR)在多中心环境下提高头颈部鳞状细胞癌18F-FDG-PET肿瘤分割的可重复性
研究分析95例头颈部癌放疗计划FDG-PET/CT,以颈段脊髓为内参照计算肿瘤与颈段脊髓标准化摄取比(SUR),用Bland-Altman法比较纵隔血池与颈段脊髓FDG摄取,并以GTV为参考真值通过非线性回归确定最佳代谢肿瘤体积(MTV)。结果显示SUR模型可重复性优于SUV模型,并在62例独立验证集中得到确认。
要点
- 纵隔血池与颈段脊髓FDG摄取具有等效性。
- 使用SUR替代SUV后模型可重复性提高,并在验证队列中确认。
- 作者认为SUR方法可能优于基于SUV的方法。
核心结论
- 在多中心环境下,使用肿瘤与颈段脊髓SUR替代SUV可提高FDG-PET/CT确定MTV模型的可重复性。
- 本研究提示SUR方法可能优于基于SUV的方法。
研究设计与样本
- 分析95例头颈部癌患者的放疗计划FDG-PET/CT扫描,采用Bland-Altman法评估颈段脊髓与纵隔血池FDG摄取的差异,并以GTV为参考真值、空间重叠指数为统计验证指标,通过非线性回归确定最佳MTV。
- 可重复性采用Bland-Altman法评估,并在由62例患者组成的独立数据集中进行外部验证。
主要发现
- Bland-Altman分析显示纵隔血池与颈段脊髓的FDG摄取具有等效性。
- 使用SUR替代SUV后模型可重复性改善,该结果在验证队列中得到确认。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In quantitative FDG-PET data analysis, normalization of the standardized uptake value (SUV) with an internal image-derived standard improves its reproducibility. In this study, the cervical spinal cord is proposed as an internal standard that is within the field of view of the radiotherapy planning PET/CT-scan in head and neck cancer. The aim is to evaluate if the tumor to cervical spinal cord standardized uptake ratio (SUR) can improve the reproducibility of a model to determine the metabolic tumor volume (MTV) on FDG-PET/CT in a multicenter setting. MATERIALS AND METHODS: Ninety-five radiotherapy planning FDG-PET/CT-scans of patients with head and neck cancer were analyzed using the Bland-Altman method to evaluate differences in FDG-uptake in the cervical spinal cord and the mediastinal blood pool. Non-linear regression analysis was used to determine the optimal MTV using the gross tumor volume (GTV) as ground truth and a spatial overlap-index as statistical validation metric. Reproducibility was evaluated using the Bland-Altman method and external validation was performed in an independent dataset consisting of 62 patients. RESULTS: Bland-Altman's analyses demonstrated equivalence of FDG-uptake in the mediastinal blood pool and the cervical spinal cord. Reproducibility of the models improved when using SUR instead of SUV. These results were confirmed in the validation cohort. CONCLUSION: The use of the tumor to cervical spinal cord SUR instead of SUV improves the reproducibility of a model to determine the MTV on FDG-PET/CT in a multicenter setting. This study indicates that SUR may be preferred over SUV based approaches.
引用
- van den Bosch S, Dijkema T, Philippens MEP, et al. Tumor to cervical spinal cord standardized uptake ratio (SUR) improves the reproducibility of 18F-FDG-PET based tumor segmentation in head and neck squamous cell carcinoma in a multicenter setting. Radiother Oncol. 2018. PMID: 30005954. doi:10.1016/j.radonc.2018.06.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。