腮腺脂肪相关磁共振影像生物标志物改善晚期放射性口干预测
本研究纳入68例头颈癌患者,从治疗前T1加权磁共振图像提取腮腺影像生物标志物,评估其与放疗后12个月口干(Xer12m)的关联,并检验脂肪与功能腮腺组织比值与Xer12m相关的假说,同时在25例外部队列验证。结果显示高强度影像标志物P90与Xer12m风险升高显著相关,并将内部验证AUC从0.78提升至0.83。
要点
- 治疗前腮腺磁共振影像生物标志物P90与放疗后12个月口干风险升高显著相关。
- P90模型内部验证AUC从参考模型0.78提升至0.83(似然比检验p=0.002)。
- 外部验证队列中P90模型AUC为0.83,优于参考模型AUC=0.65。
核心结论
- 治疗前磁共振影像生物标志物与放射性口干相关,支持腮腺内预存脂肪量与放疗后12个月口干相关的假说。
- 与基于腮腺剂量和基线口干的参考模型相比,磁共振影像生物标志物改善了口干预测。
研究设计与样本
- 从68例头颈癌患者治疗前T1加权磁共振图像提取腮腺影像生物标志物,经脂肪组织归一化,量化21个强度特征和43个纹理特征。
- 采用自举向前选择后的多变量逻辑回归模型,与逻辑回归参考模型比较性能,并在25例头颈癌患者的小型外部队列中检验有效性。
主要发现
- 高强度影像生物标志物P90(第90强度百分位数)值与Xer12m风险升高显著相关,高P90值与腮腺内高脂肪浓度相关。
- P90显著改善Xer12m预测模型性能(似然比检验p=0.002),内部验证AUC从参考模型0.78升至P90模型0.83。
- 外部验证队列中P90模型AUC=0.83,优于参考模型AUC=0.65。
局限性
- 外部验证队列样本量小,仅25例头颈癌患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: This study investigated whether Magnetic Resonance image biomarkers (MR-IBMs) were associated with xerostomia 12 months after radiotherapy (Xer12m) and to test the hypothesis that the ratio of fat-to-functional parotid tissue is related to Xer12m. Additionally, improvement of the reference Xer12m model based on parotid gland dose and baseline xerostomia, with MR-IBMs was explored. METHODS: Parotid gland MR-IBMs of 68 head and neck cancer patients were extracted from pre-treatment T1-weighted MR images, which were normalized to fat tissue, quantifying 21 intensity and 43 texture image characteristics. The performance of the resulting multivariable logistic regression models after bootstrapped forward selection was compared with that of the logistic regression reference model. Validity was tested in a small external cohort of 25 head and neck cancer patients. RESULTS: High intensity MR-IBM P90 (the 90th intensity percentile) values were significantly associated with a higher risk of Xer12m. High P90 values were related to high fat concentration in the parotid glands. The MR-IBM P90 significantly improved model performance in predicting Xer12m (likelihood-ratio-test; p = 0.002), with an increase in internally validated AUC from 0.78 (reference model) to 0.83 (P90). The MR-IBM P90 model also outperformed the reference model (AUC = 0.65) on the external validation cohort (AUC = 0.83). CONCLUSION: Pre-treatment MR-IBMs were associated to radiation-induced xerostomia, which supported the hypothesis that the amount of predisposed fat within the parotid glands is associated with Xer12m. In addition, xerostomia prediction was improved with MR-IBMs compared to the reference model.
引用
- van Dijk LV, Thor M, Steenbakkers RJHM, et al. Parotid gland fat related Magnetic Resonance image biomarkers improve prediction of late radiation-induced xerostomia. Radiother Oncol. 2018. PMID: 29958772. doi:10.1016/j.radonc.2018.06.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。