文献速递头颈部肿瘤放疗放疗物理与技术

头颈部肿瘤放疗期间的解剖变化及其对脊髓实际受照剂量的影响

Anatomical change during radiotherapy for head and neck cancer, and its effect on delivered dose to the spinal cord.
PubMed 文献 · Radiother Oncol · 2018-07-23

研究纳入133例接受TomoTherapy每日兆伏级CT图像引导的头颈部肿瘤患者,将计划扫描的脊髓轮廓形变配准至MVCT-IG扫描并累积剂量,比较计划与实际的脊髓D2%。结果显示实际与计划脊髓D2%平均差值为-0.07 Gy,即使体重明显下降或解剖变化显著,也未观察到其与脊髓D2%变化的关系。

要点

  • 每日图像引导下,实际与计划脊髓D2%平均差值仅-0.07 Gy(95%CI -0.28至0.14)。
  • 颈部照射策略(p=0.39)与T分期(p=0.56)不影响脊髓D2%变化。
  • 体重下降6.8 kg及解剖指标明显缩小,但均与脊髓D2%变化无关(所有r²<0.1)。

核心结论

  • 在每日图像引导治疗的患者中,实际与计划脊髓D2%差异很小。
  • 即使治疗期间体重明显下降或解剖变化显著,也不需要为脊髓安全进行调整再计划。

研究设计与样本

  • 选取133例在TomoTherapy上接受每日兆伏级CT图像引导(MVCT-IG)治疗的头颈部肿瘤患者。
  • 使用Elastix软件将计划扫描的脊髓轮廓形变配准至MVCT-IG扫描并累积剂量,比较计划(DP)与实际(DA)脊髓D2%(SCD2%)。
  • 分析颈部照射策略(单侧 vs 双侧)、T分期、N分期、体重下降以及C1和甲状腺上切迹(TN)处侧向分离(LND)与CT层面表面积(SSA)变化与ΔSCD2%的单变量关系。

主要发现

  • (DA-DP)D2%平均值为-0.07 Gy(95%CI -0.28至0.14,范围-5.7 Gy至3.8 Gy)。
  • DP与DA之间平均绝对差值为0.9 Gy(95%CI 0.76-1.04 Gy)。
  • 颈部治疗策略(p=0.39)和T分期(p=0.56)不影响ΔSCD2%。
  • 较高N分期(N2-3)与较高ΔSCD2%呈临界显著性(p=0.09)。
  • 解剖指标平均缩小明显:体重下降6.8 kg、C1LND 12.9 mm、C1SSA 12.1 cm2、TNLND 5.3 mm、TNSSA 11.2 cm2,但体重下降或解剖变化与ΔSCD2%均无关系(所有r²<0.1)。

临床怎么用

  • 作者认为,接受每日图像引导治疗的患者即使治疗期间体重明显下降或解剖变化显著,也不需要为脊髓安全进行调整再计划。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: The impact of weight loss and anatomical change during head and neck (H&N) radiotherapy on spinal cord dosimetry is poorly understood, limiting evidence-based adaptive management strategies. MATERIALS AND METHODS: 133 H&N patients treated with daily mega-voltage CT image-guidance (MVCT-IG) on TomoTherapy, were selected. Elastix software was used to deform planning scan SC contours to MVCT-IG scans, and accumulate dose. Planned (DP) and delivered (DA) spinal cord D2% (SCD2%) were compared. Univariate relationships between neck irradiation strategy (unilateral vs bilateral), T-stage, N-stage, weight loss, and changes in lateral separation (LND) and CT slice surface area (SSA) at C1 and the superior thyroid notch (TN), and ΔSCD2% [(DA - DP) D2%] were examined. RESULTS: The mean value for (DA - DP) D2% was -0.07 Gy (95%CI -0.28 to 0.14, range -5.7 Gy to 3.8 Gy), and the mean absolute difference between DP and DA (independent of difference direction) was 0.9 Gy (95%CI 0.76-1.04 Gy). Neck treatment strategy (p = 0.39) and T-stage (p = 0.56) did not affect ΔSCD2%. Borderline significance (p = 0.09) was seen for higher N-stage (N2-3) and higher ΔSCD2%. Mean reductions in anatomical metrics were substantial: weight loss 6.8 kg; C1LND 12.9 mm; C1SSA 12.1 cm2; TNLND 5.3 mm; TNSSA 11.2 cm2, but no relationship between weight loss or anatomical change and ΔSCD2% was observed (all r2 < 0.1). CONCLUSIONS: Differences between delivered and planned spinal cord D2% are small in patients treated with daily IG. Even patients experiencing substantial weight loss or anatomical change during treatment do not require adaptive replanning for spinal cord safety.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Noble DJ, Yeap PL, Seah SYK, et al. Anatomical change during radiotherapy for head and neck cancer, and its effect on delivered dose to the spinal cord. Radiother Oncol. 2018. PMID: 30049455. doi:10.1016/j.radonc.2018.07.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。