经皮CT引导肺结节活检使用隧道密封剂后对高精度放疗计划或局限切除的启示
本研究评估406例肿瘤患者经隧道密封剂行肺活检后,326例有随访CT者中234例(72%)出现肺活检隧道(LBT),仅4例(1.7%)疑恶性隧道种植(MTS),且MTS仅见于胸外恶性肿瘤转移患者,原发性肺癌患者中未见MTS。作者认为仅对拟行立体定向体部放疗或楔形切除的LBT合并胸外恶性肿瘤患者考虑调整治疗方案。
要点
- 326例有随访CT的肺活检中234例(72%)出现LBT,多在活检后0至3个月识别。
- LBT多呈直线或蛇形,厚度2至5mm,92%不变、6.3%缩小。
- 疑MTS仅4/234例(1.7%),均发生于胸外恶性肿瘤转移活检后,原发性肺癌未见。
核心结论
- 使用隧道密封剂的肺活检后LBT在CT上常见。
- MTS不常见,且仅发生于胸外恶性肿瘤患者,原发性肺癌患者中未见MTS。
- 因此,仅对存在LBT且为胸外恶性肿瘤、正在考虑立体定向体部放疗或楔形切除的患者考虑调整 planned therapy。
研究设计与样本
- 19个月内对肿瘤患者行406例使用隧道密封剂的肺活检,其中326例有随访CT并纳入研究组。
- 由4名胸部放射科医生回顾性分析影像,1名病理科医生检查10例切除的LBT。
主要发现
- 326例活检中234例(72%)CT显示LBT,包括原发性肺癌98例、转移瘤81例、良性50例、无法诊断5例。
- LBT在活检后0至3个月于影像上识别,典型呈直线或蛇形,厚度2至5mm。
- 随时间推移,大多数LBT不变(92%)或缩小(6.3%)。
- 疑MTS的LBT厚度增加/结节化发生于234例活检中的4例(1.7%)。
- MTS仅发生于胸外恶性肿瘤转移活检后,肺癌患者中未见发生。
关键数值与推荐
- LBT出现率:234/326例活检(72%)。
- 疑MTS发生率:4/234例活检(1.7%)。
- LBT随访变化:不变92%、缩小6.3%。
- LBT厚度:2至5mm;识别时间:活检后0至3个月。
临床怎么用
- 作者认为,仅对存在LBT且为胸外恶性肿瘤、正在考虑立体定向体部放疗或楔形切除的患者考虑调整 planned therapy。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Precision radiation therapy such as stereotactic body radiation therapy and limited resection are being used more frequently to treat intrathoracic malignancies. Effective local control requires precise radiation target delineation or complete resection. Lung biopsy tracts (LBT) on computed tomography (CT) scans after the use of tract sealants can mimic malignant tract seeding (MTS) and it is unclear whether these LBTs should be included in the calculated tumor volume or resected. This study evaluates the incidence, appearance, evolution, and malignant seeding of LBTs. METHODS AND MATERIALS: A total of 406 lung biopsies were performed in oncology patients using a tract sealant over 19 months. Of these patients, 326 had follow-up CT scans and were included in the study group. Four thoracic radiologists retrospectively analyzed the imaging, and a pathologist examined 10 resected LBTs. RESULTS: A total of 234 of 326 biopsies (72%, including primary lung cancer [n = 98]; metastases [n = 81]; benign [n = 50]; and nondiagnostic [n = 5]) showed an LBT on CT. LBTs were identified on imaging 0 to 3 months after biopsy. LBTs were typically straight or serpiginous with a thickness of 2 to 5 mm. Most LBTs were unchanged (92%) or decreased (6.3%) over time. An increase in LBT thickness/nodularity that was suspicious for MTS occurred in 4 of 234 biopsies (1.7%). MTS only occurred after biopsy of metastases from extrathoracic malignancies, and none occurred in patients with lung cancer. CONCLUSIONS: LBTs are common on CT after lung biopsy using a tract sealant. MTS is uncommon and only occurred in patients with extrathoracic malignancies. No MTS was found in patients with primary lung cancer. Accordingly, potential alteration in planned therapy should be considered only in patients with LBTs and extrathoracic malignancies being considered for stereotactic body radiation therapy or wedge resection.
引用
- de Groot PM, Shroff GS, Ahrar J, et al. Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant. Adv Radiat Oncol. 2017. PMID: 29904738. doi:10.1016/j.adro.2017.12.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。