PubMed 文献 · Int J Radiat Oncol Biol Phys · 2018-05-02

该回顾性研究纳入26例肺癌患者,利用虚拟支气管镜系统分割支气管树并形变配准至计划CT,建立基于最大点剂量和直径的气道塌陷风险模型,并将该风险函数纳入治疗计划目标函数。结果显示直径、Dmax和吸烟包年与气道节段塌陷独立相关,基于风险管理的计划可在满足临床剂量学目标的同时显著降低气道节段剂量。

要点

  • 单因素分析显示气道节段直径(P=.014)和Dmax(P=.007)与气道节段塌陷显著相关。
  • 多因素逐步Cox回归显示直径(P=.015)、Dmax(P<.0001)和吸烟包年(P=.02)是塌陷的显著独立因素。
  • 基于风险管理的计划在满足临床剂量学目标的同时显著降低了各气道节段的剂量。

核心结论

  • 据作者所知,这是首个基于标测和最小化各支气管节段剂量来实现肺SAbR功能性回避的系统性研究,早期结果显示可大幅降低气道剂量,可能降低放射性气道损伤风险,同时满足临床处方剂量学目标。

研究设计与样本

  • 回顾性收集26例肺癌患者SAbR前后诊断质量CT扫描,使用虚拟支气管镜系统分割支气管树并形变配准至计划CT。
  • 采用单因素和逐步多因素Cox回归分析年龄、合并症、吸烟包年、气道直径和最大点剂量(Dmax)等因素,并用逻辑回归构建基于Dmax和直径的节段塌陷风险函数。
  • 将风险函数与PTV和OARs的临床剂量体积约束一起纳入目标函数进行治疗计划设计。

主要发现

  • 单因素分析显示节段直径(P=.014)和Dmax(P=.007)与气道节段塌陷显著相关。
  • 多因素逐步Cox回归显示直径(P=.015)、Dmax(P<.0001)和吸烟包年(P=.02)是与塌陷显著相关的独立因素。
  • 基于风险管理的计划在满足临床剂量学目标的同时,使各气道节段剂量显著降低。

关键数值与推荐

  • 单因素分析中节段直径P=.014、Dmax P=.007与气道节段塌陷显著相关。
  • 多因素逐步Cox回归中直径P=.015、Dmax P<.0001、吸烟包年P=.02为塌陷的显著独立因素。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Radiation injury to the bronchial tree is an important yet poorly understood potential side effect in lung stereotactic ablative radiation therapy (SAbR). We investigate the integration of virtual bronchoscopy in radiation therapy planning to quantify dosage to individual airways. We develop a risk model of airway collapse and develop treatment plans that reduce the risk of radiation-induced airway injury. METHODS AND MATERIALS: Pre- and post-SAbR diagnostic-quality computerized tomography (CT) scans were retrospectively collected from 26 lung cancer patients. From each scan, the bronchial tree was segmented using a virtual bronchoscopy system and registered deformably to the planning CT. Univariate and stepwise multivariate Cox regressions were performed, examining factors such as age, comorbidities, smoking pack years, airway diameter, and maximum point dosage (Dmax). Logistic regression was utilized to formulate a risk function of segmental collapse based on Dmax and diameter. The risk function was incorporated into the objective function along with clinical dosage volume constraints for planning target volume (PTV) and organs at risk (OARs). RESULTS: Univariate analysis showed that segmental diameter (P = .014) and Dmax (P = .007) were significantly correlated with airway segment collapse. Multivariate stepwise Cox regression showed that diameter (P = .015), Dmax (P < .0001), and pack/years of smoking (P = .02) were significant independent factors associated with collapse. Risk management-based plans enabled significant dosage reduction to individual airway segments while fulfilling clinical dosimetric objectives. CONCLUSION: To our knowledge, this is the first systematic investigation of functional avoidance in lung SAbR based on mapping and minimizing doses to individual bronchial segments. Our early results show that it is possible to substantially lower airway dosage. Such dosage reduction may potentially reduce the risk of radiation-induced airway injury, while satisfying clinically prescribed dosimetric objectives.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Kazemzadeh N, Modiri A, Samanta S, et al. Virtual Bronchoscopy-Guided Treatment Planning to Map and Mitigate Radiation-Induced Airway Injury in Lung SAbR. Int J Radiat Oncol Biol Phys. 2018. PMID: 29891202. doi:10.1016/j.ijrobp.2018.04.060