荧光核径迹探测器用于α辐射微剂量学
研究用荧光核径迹探测器测量外部镅-241 α源照射的U87胶质母细胞瘤细胞,结合高分辨率3D细胞几何图像计算核剂量分布。实验微剂量学参数用于模拟不同同位素空间分布的3D U87细胞球体,评估核剂量分布对预期细胞存活的影响。结果与解析推导的核剂量分布吻合良好,细胞质和细胞膜上同位素的相对效能与外部照射差异小于5%,而核内或核膜上同位素相对效能增加33-51%。
要点
- 荧光核径迹探测器可亚微米分辨率测量单个α粒子,获得准确的能量、注量和剂量率。
- 细胞质和细胞膜上同位素相对效能与外部照射差异小于5%。
- 核内或核膜上同位素相对效能增加33-51%。
核心结论
- 该方法易用、准确且使用实验获得的辐射场特征,优于传统基于模拟的微剂量学研究。
- 考虑到α放射性核素载体在体内和体外的未确定因素,以及相对生物效能和氧增强比的较大贡献,预期只有穿透或环绕细胞核的载体才能从微剂量学中实质获益。
研究设计与样本
- 使用外部镅-241 α源照射荧光核径迹探测器和U87胶质母细胞瘤细胞培养物。
- 用荧光核径迹探测器测量的α粒子径迹结合高分辨率3D细胞几何图像计算U87胶质母细胞瘤细胞的核剂量分布。
- 将实验获得的微剂量学参数应用于不同同位素空间分布的3D U87细胞球体模拟,评估核剂量分布对预期细胞存活的影响。
主要发现
- 新实验方法与解析推导的核剂量分布吻合良好。
- 细胞质和细胞膜上同位素与外部照射相比相对效能差异小于5%。
- 核内或核膜上同位素相对效能增加33-51%。
局限性
- α放射性核素载体在体内和体外存在未确定因素。
- 相对生物效能和氧增强比有较大贡献。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: While alpha microdosimetry dates back a couple of decades, the effects of localized energy deposition of alpha particles are often still unclear since few comparative studies have been performed. Most modern alpha microdosimetry studies rely for large parts on simulations, which negatively impacts both the simplicity of the calculations and the reliability of the results. A novel microdosimetry method based on the Fluorescent Nuclear Track Detector, a versatile tool that can measure individual alpha particles at sub-micron resolution, yielding accurate energy, fluence and dose rate measurements, was introduced to address these issues. METHODS: Both the detectors and U87 glioblastoma cell cultures were irradiated using an external Am241 alpha source. The alpha particle tracks measured with a Fluorescent Nuclear Track Detector were used together with high resolution 3D cell geometries images to calculate the nucleus dose distribution in the U87 glioblastoma cells. The experimentally obtained microdosimetry parameters were thereafter applied to simulations of 3D U87 cells cultures (spheroids) with various spatial distributions of isotopes to evaluate the effect of the nucleus dose distribution on the expected cell survival. RESULTS: The new experimental method showed good agreement with the analytically derived nucleus dose distributions. Small differences (< 5%) in the relative effectiveness were found for isotopes in the cytoplasm and on the cell membrane versus external irradiation, while isotopes located in the nucleus or on the nuclear membrane showed a substantial increase in relative effectiveness (33 - 51%). CONCLUSIONS: The ease-of-use, good accuracy and use of experimentally derived characteristics of the radiation field make this method superior to conventional simulation-based microdosimetry studies. Considering the uncertainties found in alpha radionuclide carriers in-vivo and in-vitro, together with the large contributions from the relative biological effectiveness and the oxygen enhancement ratio, it is expected that only carriers penetrating or surrounding the cell nucleus will substantially benefit from microdosimetry.
引用
- Kouwenberg JJM, Wolterbeek HT, Denkova AG, et al. Fluorescent nuclear track detectors for alpha radiation microdosimetry. Radiat Oncol. 2018. PMID: 29880059. doi:10.1186/s13014-018-1034-x