基于AutoPlanning的多准则优化用于鼻咽癌容积调强弧形治疗计划的新策略
本研究纳入60例不同分期的鼻咽癌患者,比较通用多准则优化(MCO)与AutoPlanning联合MCO(APMCO)两种容积调强弧形治疗计划方案。两种方案均能满足处方要求,靶区覆盖与适形度相似,多数危及器官保护无显著差异,但APMCO方案使声门喉和咽缩肌的平均剂量分别降低10.5%(p<0.0001)和8.4%(p<0.0001),计划时间平均增加约5小时,机器跳数未显著增加。
要点
- 60例鼻咽癌患者中,APMCO与通用MCO方案均满足处方要求,靶区覆盖和适形度相似。
- APMCO方案使声门喉平均剂量降低10.5%(p<0.0001),咽缩肌平均剂量降低8.4%(p<0.0001)。
- APMCO计划时间平均增加约5小时,机器跳数较通用MCO未显著增加。
核心结论
- APMCO策略的潜力在临床实施中通过个体化生成Pareto曲面表示而无需手动交互时得到最佳实现。
- APMCO还帮助医生以更高效和直接的方式进行导航。
研究设计与样本
- 本研究纳入60例不同分期的鼻咽癌患者,为临床前研究。
- 为每例患者在治疗计划系统上生成通用MCO和APMCO两种计划方案,并比较两种方案之间的差异。
主要发现
- 所有计划均能满足处方要求。
- 通用MCO与APMCO计划之间的靶区覆盖和适形数非常相似。
- 大多数危及器官的保护无显著差异。
- APMCO计划中声门喉和咽缩肌的平均剂量(Dmean)相对明显降低,两个危及器官的平均Dmean分别降低10.5%(p<0.0001)和8.4%(p<0.0001)。
- APMCO技术使计划时间平均增加约5小时,且与通用MCO相比未导致机器跳数显著增加。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A new strategy for making the appropriate choice of the representative optimization parameters in planning processes and accurate selection criteria during Pareto surface navigation for general multicriteria optimization (MCO) was recommended in the study. The purpose was to combine both benefits of AutoPlanning optimization and MCO (APMCO) for achieving an individual volumetric-modulated arc therapy (VMAT) plan according to the clinically achieved patient-specific tradeoff among conflicting priorities. The preclinical investigation of this optimization approach for nasopharyngeal carcinoma (NPC) radiotherapy was performed and compared to general MCO VMAT. METHODS: A total of 60 NPC patients with various stages were enrolled in this study. General MCO and APMCO plans were generated for each patient on the treatment planning system. The differences between two planning schemes were evaluated and compared. RESULTS: All plans were capable of achieving the prescription requirement. The planning target volume coverage and conformation number were remarkably similar between general MCO and APMCO plans. There were no significant differences in most of organs at risk (OARs) sparing. However, in APMCO plans, relatively remarkable decreases were observed in the mean dose (Dmean) to the glottic larynx and pharyngeal constrictor muscles. The reductions of average Dmean to the two OARs were 10.5% (p < 0.0001) and 8.4% (p < 0.0001), respectively. APMCO technique was found to increase the planning time for an average of approximately 5 h and did not lead to a significant increase of monitor units compared to general MCO. CONCLUSIONS: The potential of the APMCO strategy is best realized with a clinical implementation that exploits individual generation of Pareto surface representations without manual interaction. It also assists physicians to ensure navigation in a more efficient and straightforward manner.
引用
- Wang J, Chen Z, Li W, et al. A new strategy for volumetric-modulated arc therapy planning using AutoPlanning based multicriteria optimization for nasopharyngeal carcinoma. Radiat Oncol. 2018. PMID: 29769101. doi:10.1186/s13014-018-1042-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。