文献速递乳腺癌放疗放疗物理与技术

深度学习自动量化乳腺癌放疗计划CT中冠脉与胸主动脉钙化

Automatic quantification of calcifications in the coronary arteries and thoracic aorta on radiotherapy planning CT scans of Western and Asian breast cancer patients.
PubMed 文献 · Radiother Oncol · 2018-04-24

本研究对荷兰1199例与新加坡1090例乳腺癌患者的放疗计划CT行深度学习自动冠脉钙化(CAC)与胸主动脉钙化(TAC)评分,并以手工评分为参照评估可重复性。荷兰患者CAC与TAC检出率分别为24.2%与73.0%,高于新加坡的17.3%与62.2%,两者均随年龄增长而增加;自动与手工评分在两地均显示优良的一致性。

要点

  • 深度学习可在乳腺癌放疗计划CT上自动测量CAC与TAC,可靠性优良。
  • 荷兰患者CAC与TAC检出率高于新加坡患者,且均随年龄增加。
  • 放疗计划CT可机会性评估心血管钙化,辅助风险分层。

核心结论

  • 深度学习软件是自动测量乳腺癌放疗CT上CAC与TAC的可靠方法。
  • CAC与TAC检出率相当可观,且随年龄增长而增加。

研究设计与样本

  • 纳入荷兰(n=1199)与新加坡(n=1090)乳腺癌放疗计划CT患者,采用深度学习算法自动评分CAC与TAC。
  • CVD风险分类基于Agatson CAC:0、1-10、11-100、101-400及>400。
  • 从每人群随机抽取120例CT评估自动与手工评分一致性,CAC分类用线性加权kappa,TAC用组内相关系数。

主要发现

  • 荷兰患者中位年龄57岁,高于新加坡患者的52岁。
  • 荷兰与新加坡患者CAC检出率分别为24.2%与17.3%,TAC分别为73.0%与62.2%。
  • 荷兰CAC分类与TAC一致性分别为0.85(95%CI=0.77-0.93)与0.98(95%CI=0.96-0.98)。
  • 新加坡CAC分类与TAC一致性分别为0.90(95%CI=0.84-0.96)与0.99(95%CI=0.98-0.99)。

关键数值与推荐

  • CVD风险分类依据Agatson CAC分为0、1-10、11-100、101-400及>400五档。
  • CAC分类一致性以线性加权kappa评估,TAC以组内相关系数评估。

临床怎么用

  • 可在乳腺癌放疗计划CT上以深度学习自动量化CAC与TAC,用于机会性心血管风险识别。
  • 自动评分与手工评分一致性优良,可作为放疗科医生评估心血管钙化的辅助工具。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study automatically quantified calcifications in coronary arteries (CAC) and thoracic aorta (TAC) on breast planning computed tomography (CT) scans and assessed its reproducibility compared to manual scoring. MATERIAL AND METHODS: Dutch (n = 1199) and Singaporean (n = 1090) breast cancer patients with radiotherapy planning CT scan were included. CAC and TAC were automatically scored using deep learning algorithm. CVD risk categories were based on Agatson CAC: 0, 1-10, 11-100, 101-400 and >400. Reliability between automatic and manual scoring was assessed in 120 randomly selected CT scans from each population, with linearly weighted kappa for CAC categories and intraclass correlation coefficient for TAC. RESULTS: Median age was higher in Dutch patients than Singaporean patients: 57 versus 52 years. CAC and TAC increased with age and were more present in Dutch patients than Singaporean patients: 24.2% versus 17.3% and 73.0% versus 62.2%, respectively. Reliability of CAC categories and TAC was excellent in the Netherlands (0.85 (95% confidence interval (CI) = 0.77-0.93) and 0.98 (95% CI = 0.96-0.98) respectively) and Singapore (0.90 (95% CI = 0.84-0.96) and 0.99 (95% CI = 0.98-0.99) respectively). CONCLUSIONS: CAC and TAC prevalence was considerable and increased with age. Deep learning software is a reliable method to automatically measure CAC and TAC on radiotherapy breast CT scans.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Gernaat SAM, van Velzen SGM, Koh V, et al. Automatic quantification of calcifications in the coronary arteries and thoracic aorta on radiotherapy planning CT scans of Western and Asian breast cancer patients. Radiother Oncol. 2018. PMID: 29703498. doi:10.1016/j.radonc.2018.04.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。