胰腺癌每日自适应MR引导放疗中治疗计划工作流程与肿瘤覆盖的优化
本研究针对接受每日自适应MR-IGRT的16例胰腺癌患者,比较了传统方法(将胃、十二指肠、小肠、大肠作为独立OAR)与OAR分组方法构建初始目标函数的效果。OAR分组方法创建了包含四个主要OAR在PTV 3 cm内部分的联合OAR结构。结果显示,OAR分组计划在多数分次中改善了靶区覆盖,PTV D95覆盖平均提高3.87±4.29%,PTV OPT D95覆盖平均提高3.98±4.97%,PTV D100覆盖平均提高6.47±7.16%。结论认为OAR分组简化了自适应计划工作流程并改善了覆盖。
要点
- OAR分组方法将胃、十二指肠、小肠、大肠在PTV 3 cm内的部分合并为联合OAR结构。
- OAR分组计划使PTV D95覆盖平均提高3.87±4.29%,PTV OPT D95覆盖平均提高3.98±4.97%。
- PTV D100覆盖平均提高6.47±7.16%,最大改善达20.19%。
核心结论
- OAR分组计划在多数分次中优于传统计划,尤其当传统模拟计划通过分配不同权重参数而偏好或忽略某个OAR时。
- OAR分组简化了模拟时的MR-IGRT自适应治疗计划工作流程,并显示出比每日自适应放疗中实际交付的胰腺癌治疗计划更好的覆盖。
研究设计与样本
- 本研究对16例接受ViewRay™ MR-IGRT系统治疗的胰腺癌患者,分别用传统方法和OAR分组方法构建初始目标函数,并在每个分次基于患者每日解剖重新优化计划。
主要发现
- 使用OAR分组在多数分次中增强了计划性能。
- PTV的D95覆盖体积百分比平均提高3.87±4.29%,PTV OPT的D95覆盖平均提高3.98±4.97%。
- PTV的D100覆盖平均提高6.47±7.16%,最大改善为20.19%。
临床怎么用
- 在胰腺癌每日自适应MR-IGRT中,可采用OAR分组方法构建初始目标函数以简化工作流程并改善靶区覆盖。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To simplify the adaptive treatment planning workflow while achieving the optimal tumor-dose coverage in pancreatic cancer patients undergoing daily adaptive magnetic resonance image guided radiation therapy (MR-IGRT). METHODS: In daily adaptive MR-IGRT, the plan objective function constructed during simulation is used for plan re-optimization throughout the course of treatment. In this study, we have constructed the initial objective functions using two methods for 16 pancreatic cancer patients treated with the ViewRay™ MR-IGRT system: 1) the conventional method that handles the stomach, duodenum, small bowel, and large bowel as separate organs at risk (OARs) and 2) the OAR grouping method. Using OAR grouping, a combined OAR structure that encompasses the portions of these four primary OARs within 3 cm of the planning target volume (PTV) is created. OAR grouping simulation plans were optimized such that the target coverage was comparable to the clinical simulation plan constructed in the conventional manner. In both cases, the initial objective function was then applied to each successive treatment fraction and the plan was re-optimized based on the patient's daily anatomy. OAR grouping plans were compared to conventional plans at each fraction in terms of coverage of the PTV and the optimized PTV (PTV OPT), which is the result of the subtraction of overlapping OAR volumes with an additional margin from the PTV. RESULTS: Plan performance was enhanced across a majority of fractions using OAR grouping. The percentage of the volume of the PTV covered by 95% of the prescribed dose (D95) was improved by an average of 3.87 ± 4.29% while D95 coverage of the PTV OPT increased by 3.98 ± 4.97%. Finally, D100 coverage of the PTV demonstrated an average increase of 6.47 ± 7.16% and a maximum improvement of 20.19%. CONCLUSIONS: In this study, our proposed OAR grouping plans generally outperformed conventional plans, especially when the conventional simulation plan favored or disregarded an OAR through the assignment of distinct weighting parameters relative to the other critical structures. OAR grouping simplifies the MR-IGRT adaptive treatment planning workflow at simulation while demonstrating improved coverage compared to delivered pancreatic cancer treatment plans in daily adaptive radiation therapy.
引用
- Olberg S, Green O, Cai B, et al. Optimization of treatment planning workflow and tumor coverage during daily adaptive magnetic resonance image guided radiation therapy (MR-IGRT) of pancreatic cancer. Radiat Oncol. 2018. PMID: 29573744. doi:10.1186/s13014-018-1000-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。