心跳之间:双源CT评估心脏周期中心脏结构动态剂量变化
前瞻性研究纳入10例左侧乳腺癌拟行切线放疗患者,采用心电图同步双源CT在深吸气屏气治疗体位扫描,评估心脏周期中左前降支等心脏结构剂量变化。结果显示收缩期照射较舒张期降低左前降支、左心室和全心脏剂量。
要点
- 收缩期照射较舒张期降低左前降支、左心室和全心脏剂量。
- 全心脏最大剂量和V5在收缩期较舒张期降低。
- 双源CT可用于确定心脏重要结构的计划危及器官体积。
核心结论
- 除深吸气屏气外,收缩期照射与左前降支、左心室和全心脏剂量降低相关。
研究设计与样本
- 前瞻性研究纳入10例左侧乳腺癌拟行切线放疗患者,采用心电图同步双源CT在深吸气屏气治疗体位扫描。
关键数值与推荐
- 左心室和左主冠状动脉从收缩期到舒张期的Hausdorff距离最大、最小和平均变化≤4 mm。
- 全心脏和左前降支各段的Hausdorff距离变化≤3 mm。
- 全心脏平均剂量在整个心脏周期中保持相似。
临床怎么用
- 在深吸气屏气基础上,可考虑收缩期照射以降低左前降支、左心室和全心脏剂量。
- 双源CT成像可用于放疗计划中确定临床重要心脏结构的计划危及器官体积。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To assess radiation dose variation to the left anterior descending artery (LAD), left main coronary artery (LMCA), left ventricle (LV), and whole heart (WH) during the cardiac cycle using dual source computed tomography (DSCT). METHODS AND MATERIALS: The present prospective study included patients with left-side breast cancer planned to undergo tangential radiation therapy. An electrocardiogram-synchronized contrast-injected DSCT scan was obtained with the patient in the treatment position, in deep-inspiration breath-hold, using retrospective sequential acquisition. The WH, LV, LMCA, and proximal, middle, and distal LAD segments were contoured on each phase of the cardiac cycle. The maximum, minimum, and mean Hausdorff distance between each structure and the tangential fields was assessed in ventricular systole and diastole. Four-dimensional dose-volume histograms were used to compare the systolic and diastolic dosimetric data. RESULTS: Ten patients were enrolled. The average maximum, minimum, and mean Hausdorff distance variation from systole to diastole was ≤4 mm for the LV and LMCA and ≤3 mm for the WH and LAD segments. WH maximum dose and volume receiving 5 Gy were decreased in systole compared with diastole (42.9 Gy versus 44.5 Gy, P = .03, and 21.7 cm3 versus 27.7 cm3, P = .01), but the mean dose remained similar throughout the cycle. The maximum and mean dose to the distal LAD was 21.2 Gy versus 26.6 Gy (P = .005) and 8.6 Gy versus 13.2 Gy (P = .006) in systole versus diastole, respectively. The maximum and mean dose to the middle LAD was 18.4 Gy versus 25.1 Gy (P = .005) and 8.5 Gy versus 10.2 Gy in systole versus diastole (P = .005). The maximum dose to the LV was lower in systole than in diastole (21.5 Gy vs 26.7 Gy; P = .005). CONCLUSIONS: In addition to deep-inspiration breath-hold, systolic irradiation is associated with a reduction in dose to the LAD, LV, and WH. In addition to its potential use in radiation planning for cardiac gating, DSCT imaging can be used to help define a planning organ at risk volume for clinically important cardiac substructures.
引用
- Bahig H, de Guise J, Vu T, et al. In a Heartbeat: An Assessment of Dynamic Dose Variation to Cardiac Structures Using Dual Source Computed Tomography. Int J Radiat Oncol Biol Phys. 2018. PMID: 29559290. doi:10.1016/j.ijrobp.2018.01.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。