文献速递胸部肿瘤放疗放疗物理与技术

斑点尺寸与间距对肺癌鲁棒优化调强质子治疗计划质量的影响

Impact of Spot Size and Spacing on the Quality of Robustly Optimized Intensity Modulated Proton Therapy Plans for Lung Cancer.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2018-02-14

本研究对10例肺癌患者分别用大斑点机器和小斑点机器生成鲁棒优化调强质子治疗(IMPT)计划,比较计划质量、鲁棒性与交互效应。结果显示小斑点机器在靶区覆盖与均匀性可比的前提下显著降低心脏和食管平均剂量,计划鲁棒性与交互效应相当。

要点

  • 小斑点机器较大斑点机器显著降低心脏与食管平均剂量。
  • 两者靶区覆盖、均匀性及其他危及器官保护可比。
  • 小斑点机器用更多斑点覆盖同一肿瘤,为计划系统提供更大补偿自由度。

核心结论

  • 小斑点机器鲁棒优化较大斑点机器显著改善心脏和食管保护,计划鲁棒性与交互效应相当。

研究设计与样本

  • 对10例肺癌患者分别用大斑点机器(等中心空气中能量依赖大斑点尺寸σ为6-15 mm、间距1.3σ)和小斑点机器(σ为2-6 mm、间距5 mm)生成鲁棒优化IMPT计划。
  • 两计划均在平均4D-CT上以内部靶区体积为优化对象,由自研IMPT计划系统生成。
  • 用剂量体积直方图带法评估鲁棒性,并开发剂量评估软件建模时间依赖斑点投照以纳入交互效应。
  • 通过可变形图像配准进行逐相位解剖映射,用自研软件评分剂量,采用Wilcoxon符号秩检验比较剂量体积直方图指标。

主要发现

  • 较小斑点机器较大斑点机器显著降低心脏和食管平均剂量,靶区覆盖、均匀性及其他危及器官保护可比。
  • 靶区与多数危及器官的计划鲁棒性两者可比。
  • 考虑交互效应后,较小斑点仍显示心脏和食管平均剂量显著更低,靶区覆盖与均匀性可比。

临床怎么用

  • 肺癌鲁棒优化IMPT可优先考虑小斑点机器以改善心脏和食管保护,同时保持靶区覆盖与鲁棒性。

局限性

  • 研究仅纳入10例肺癌患者,为计划比较研究,非临床结局研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate how spot size and spacing affect plan quality, robustness, and interplay effects of robustly optimized intensity modulated proton therapy (IMPT) for lung cancer. METHODS AND MATERIALS: Two robustly optimized IMPT plans were created for 10 lung cancer patients: first by a large-spot machine with in-air energy-dependent large spot size at isocenter (σ: 6-15 mm) and spacing (1.3 σ), and second by a small-spot machine with in-air energy-dependent small spot size (σ: 2-6 mm) and spacing (5 mm). Both plans were generated by optimizing radiation dose to internal target volume on averaged 4-dimensional computed tomography scans using an in-house-developed IMPT planning system. The dose-volume histograms band method was used to evaluate plan robustness. Dose evaluation software was developed to model time-dependent spot delivery to incorporate interplay effects with randomized starting phases for each field per fraction. Patient anatomy voxels were mapped phase-to-phase via deformable image registration, and doses were scored using in-house-developed software. Dose-volume histogram indices, including internal target volume dose coverage, homogeneity, and organs at risk (OARs) sparing, were compared using the Wilcoxon signed-rank test. RESULTS: Compared with the large-spot machine, the small-spot machine resulted in significantly lower heart and esophagus mean doses, with comparable target dose coverage, homogeneity, and protection of other OARs. Plan robustness was comparable for targets and most OARs. With interplay effects considered, significantly lower heart and esophagus mean doses with comparable target dose coverage and homogeneity were observed using smaller spots. CONCLUSIONS: Robust optimization with a small spot-machine significantly improves heart and esophagus sparing, with comparable plan robustness and interplay effects compared with robust optimization with a large-spot machine. A small-spot machine uses a larger number of spots to cover the same tumors compared with a large-spot machine, which gives the planning system more freedom to compensate for the higher sensitivity to uncertainties and interplay effects for lung cancer treatments.