文献速递头颈部肿瘤放疗放疗物理与技术

深度学习算法自动勾画高危口咽临床靶区并内置DSC参数优化

Deep Learning Algorithm for Auto-Delineation of High-Risk Oropharyngeal Clinical Target Volumes With Built-In Dice Similarity Coefficient Parameter Optimization Function.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2018-02-07

预测靶区与医生手动勾画相比中位DSC为0.81,表明预测轮廓与基准高度一致,可临床实施且仅需微小或无修改。

要点

  • 深度学习算法可自动勾画口咽癌高危临床靶区,中位DSC达0.81。
  • 内置基于DSC的概率阈值优化函数提升预测体积的泛化能力。
  • 预测轮廓与医生手动勾画高度一致,临床实施仅需微小或无修改。

核心结论

  • 深度学习算法自动勾画的高危口咽临床靶区与医生手动勾画高度一致,优于当前观察者间变异,可临床实施且仅需微小或无修改。

研究设计与样本

  • 开发基于深度自编码器的深度学习算法,以周围解剖结构和大体肿瘤体积的距离图信息为输入,进行体素分类识别高危临床靶区。
  • 开发基于Dice相似系数(DSC)的概率阈值选择函数,在内层交叉验证循环中实施,并在模型参数优化时先验选择概率阈值。

主要发现

  • 预测体积与医生手动轮廓相比,中位DSC值为0.81(范围0.62-0.90)。
  • 中位平均表面距离为2.8 mm(范围1.6-5.5)。
  • 中位95% Hausdorff距离为7.5 mm(范围4.7-17.9)。

临床怎么用

  • 预测的高危临床靶区轮廓可临床实施,仅需微小或无修改。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Automating and standardizing the contouring of clinical target volumes (CTVs) can reduce interphysician variability, which is one of the largest sources of uncertainty in head and neck radiation therapy. In addition to using uniform margin expansions to auto-delineate high-risk CTVs, very little work has been performed to provide patient- and disease-specific high-risk CTVs. The aim of the present study was to develop a deep neural network for the auto-delineation of high-risk CTVs. METHODS AND MATERIALS: Fifty-two oropharyngeal cancer patients were selected for the present study. All patients were treated at The University of Texas MD Anderson Cancer Center from January 2006 to August 2010 and had previously contoured gross tumor volumes and CTVs. We developed a deep learning algorithm using deep auto-encoders to identify physician contouring patterns at our institution. These models use distance map information from surrounding anatomic structures and the gross tumor volume as input parameters and conduct voxel-based classification to identify voxels that are part of the high-risk CTV. In addition, we developed a novel probability threshold selection function, based on the Dice similarity coefficient (DSC), to improve the generalization of the predicted volumes. The DSC-based function is implemented during an inner cross-validation loop, and probability thresholds are selected a priori during model parameter optimization. We performed a volumetric comparison between the predicted and manually contoured volumes to assess our model. RESULTS: The predicted volumes had a median DSC value of 0.81 (range 0.62-0.90), median mean surface distance of 2.8 mm (range 1.6-5.5), and median 95th Hausdorff distance of 7.5 mm (range 4.7-17.9) when comparing our predicted high-risk CTVs with the physician manual contours. CONCLUSIONS: These predicted high-risk CTVs provided close agreement to the ground-truth compared with current interobserver variability. The predicted contours could be implemented clinically, with only minor or no changes.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Cardenas CE, McCarroll RE, Court LE, et al. Deep Learning Algorithm for Auto-Delineation of High-Risk Oropharyngeal Clinical Target Volumes With Built-In Dice Similarity Coefficient Parameter Optimization Function. Int J Radiat Oncol Biol Phys. 2018. PMID: 29559291. doi:10.1016/j.ijrobp.2018.01.114

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。