指南与共识中枢神经肿瘤放疗放疗物理与技术

欧洲粒子治疗网络基于共识的神经肿瘤学CT与MR勾画图谱

The EPTN consensus-based atlas for CT- and MR-based contouring in neuro-oncology.
指南 / 共识 · Radiother Oncol · 2018-03-13

PURPOSE: To create a digital, online atlas for organs at risk (OAR) delineation in neuro-oncology based on high-quality computed tomography (CT) and magnetic resonance (MR) imaging.…

要点

  • 图谱基于CT与3T MR融合图像及7T MR图像构建,在线提供轴位、冠状位和矢状位视图。
  • 建议将该图谱用于光子和粒子治疗,以减少OAR勾画的观察者间和观察者内变异。

核心结论

  • 为减少神经肿瘤学相关OAR勾画的观察者间和观察者内变异并推导一致的剂量学数据,建议将该图谱用于光子和粒子治疗。

研究设计与样本

  • 基于同一患者的高质量CT和3T MR图像(层厚1 mm,含静脉对比剂)融合,以及健康志愿者的7T MR图像(不含静脉对比剂),由经验丰富的放射肿瘤学家讨论确定OAR,经欧洲放射肿瘤学家评审至共识。

主要发现

  • 在线图谱包含一个CT扫描(两种窗设置)和一个MR扫描(3T),展示OAR的轴位、冠状位和矢状位视图。

关键数值与推荐

  • 图谱在线发布于www.cancerdata.org,并根据需要更新。

临床怎么用

  • 建议在光子与粒子治疗中采用该图谱进行神经肿瘤学OAR勾画,以减少观察者间和观察者内变异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To create a digital, online atlas for organs at risk (OAR) delineation in neuro-oncology based on high-quality computed tomography (CT) and magnetic resonance (MR) imaging. METHODS: CT and 3 Tesla (3T) MR images (slice thickness 1 mm with intravenous contrast agent) were obtained from the same patient and subsequently fused. In addition, a 7T MR without intravenous contrast agent was obtained from a healthy volunteer. Based on discussion between experienced radiation oncologists, the clinically relevant organs at risk (OARs) to be included in the atlas for neuro-oncology were determined, excluding typical head and neck OARs previously published. The draft atlas was delineated by a senior radiation oncologist, 2 residents in radiation oncology, and a senior neuro-radiologist incorporating relevant available literature. The proposed atlas was then critically reviewed and discussed by European radiation oncologists until consensus was reached. RESULTS: The online atlas includes one CT-scan at two different window settings and one MR scan (3T) showing the OARs in axial, coronal and sagittal view. This manuscript presents the three-dimensional descriptions of the fifteen consensus OARs for neuro-oncology. Among these is a new OAR relevant for neuro-cognition, the posterior cerebellum (illustrated on 7T MR images). CONCLUSION: In order to decrease inter- and intra-observer variability in delineating OARs relevant for neuro-oncology and thus derive consistent dosimetric data, we propose this atlas to be used in photon and particle therapy. The atlas is available online at www.cancerdata.org and will be updated whenever required.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Eekers DB, In 't Ven L, Roelofs E, et al. The EPTN consensus-based atlas for CT- and MR-based contouring in neuro-oncology. Radiother Oncol. 2018. PMID: 29548560. doi:10.1016/j.radonc.2017.12.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。