本研究利用咽黏膜放疗剂量(剂量-体积及空间剂量指标)与临床数据建立严重急性吞咽困难的预测模型,采用惩罚逻辑回归、支持向量分类和随机森林分类建模,并内部(173例)和外部(90例)验证。基于剂量-体积指标的惩罚逻辑回归模型外部验证区分度很好(AUC=0.82),随机森林显示接受1 Gy/次及以上的咽黏膜体积、长度和周长重要性最高。应尽量减少接受1 Gy/次及以上的咽黏膜体积以降低严重急性吞咽困难发生率。

要点

  • 基于剂量-体积指标的惩罚逻辑回归模型外部验证AUC=0.82。
  • 随机森林中重要性最高的特征为接受1 Gy/次及以上的咽黏膜体积、长度和周长。
  • 建议尽量减少接受1 Gy/次及以上的咽黏膜体积。

核心结论

  • 基于剂量-体积指标的惩罚逻辑回归模型在外部验证中区分度很好(AUC=0.82),与更复杂模型表现相当。
  • 应尽量减少接受1 Gy/次及以上的咽黏膜体积,以降低严重急性吞咽困难的发生率。

研究设计与样本

  • 利用咽黏膜放疗剂量(剂量-体积和空间剂量指标)与临床数据开发严重急性吞咽困难模型。
  • 生成惩罚逻辑回归、支持向量分类和随机森林分类模型,并进行内部(173例)和外部(90例)验证。
  • 使用受试者工作特征曲线下面积(AUC)比较模型性能,并用随机森林模型探索治疗特征与吞咽困难的关联。

主要发现

  • 基于剂量-体积指标的惩罚逻辑回归模型(PLRstandard)表现与更复杂模型相当,外部验证AUC=0.82。
  • 随机森林重要性最高的特征为接受1 Gy/次及以上的咽黏膜体积、长度和周长。

关键数值与推荐

  • 外部验证AUC=0.82(基于剂量-体积指标的惩罚逻辑回归模型)。
  • 随机森林重要性最高的特征为接受1 Gy/次及以上的咽黏膜体积、长度和周长。

临床怎么用

  • 该模型可预测个体患者严重急性吞咽困难的风险,辅助临床决策。
  • 放疗计划设计时应尽量减少接受1 Gy/次及以上的咽黏膜体积。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Severe acute dysphagia commonly results from head and neck radiotherapy (RT). A model enabling prediction of severity of acute dysphagia for individual patients could guide clinical decision-making. Statistical associations between RT dose distributions and dysphagia could inform RT planning protocols aiming to reduce the incidence of severe dysphagia. We aimed to establish such a model and associations incorporating spatial dose metrics. Models of severe acute dysphagia were developed using pharyngeal mucosa (PM) RT dose (dose-volume and spatial dose metrics) and clinical data. Penalized logistic regression (PLR), support vector classification and random forest classification (RFC) models were generated and internally (173 patients) and externally (90 patients) validated. These were compared using area under the receiver operating characteristic curve (AUC) to assess performance. Associations between treatment features and dysphagia were explored using RFC models. The PLR model using dose-volume metrics (PLRstandard) performed as well as the more complex models and had very good discrimination (AUC = 0.82) on external validation. The features with the highest RFC importance values were the volume, length and circumference of PM receiving 1 Gy/fraction and higher. The volumes of PM receiving 1 Gy/fraction or higher should be minimized to reduce the incidence of severe acute dysphagia.

来源:Clin Transl Radiat Oncol,查看原文。版权归原作者所有。