T2 mapping与mDIXON Quant成像早期评估鼻咽癌放疗后腮腺损伤
结论认为这两种成像技术可用于无创评估放射性腮腺损伤。
要点
- 放疗中腮腺体积缩小27.0±11.5%,T2值和FF值分别升高6.0±6.2%和9.1±9.9%。
- 放疗后T2值继续升高4.6±7.7%,FF值下降9.9±18.2%。
- T2值变化率与腮腺萎缩率显著相关(r=0.313,P=0.027)。
核心结论
- T2 mapping和mDIXON Quant成像可用于无创评估放射性腮腺损伤。
研究设计与样本
- 记录并分析腮腺体积、T2值、脂肪分数(FF)值和平均放疗剂量。
主要发现
- 从放疗前到放疗中,腮腺体积下降(萎缩率27.0±11.5%),T2值变化率6.0±6.2%、FF值变化率9.1±9.9%均显著升高。
- 从放疗中到放疗后,T2值继续升高(变化率4.6±7.7%),FF值下降(变化率-9.9±18.2%)。
- 从放疗前到放疗后,T2值变化率与腮腺萎缩率显著相关(r=0.313,P=0.027)。
- 多元线性回归显示腮腺T2值(标准化系数[SC]=-0.259,P=0.001)和FF值(SC=-0.320,P=0.014)与腮腺体积负相关,T2值与MR扫描时间点正相关(SC=0.476,P=0.001)。
- 腮腺T2值和FF值重复性极好(组内相关系数0.935-0.992)。
临床怎么用
- 可考虑将T2 mapping和mDIXON Quant成像作为鼻咽癌放疗期间及放疗后早期监测腮腺损伤的无创影像学工具。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Radiation-induced parotid damage is a common complication in patients with nasopharyngeal carcinoma (NPC) treated with radiotherapy to head and neck region, which severely reduce the life quality of those patients. The aim of this study was to early evaluate the changes of irradiated parotid glands with T2 mapping and mDIXON Quant imaging. METHODS: Forty-one patients with NPC underwent conventional magnetic resonance imaging for nasopharynx and neck, and T2 mapping and mDIXON Quant imaging for bilateral parotid glands within 2 weeks before radiotherapy (pre-RT), 5 weeks after the beginning of radiotherapy (mid-RT), and 4 weeks after radiotherapy (post-RT). Parotid volume, T2 values, fat fraction (FF) values, and mean radiation dose were recorded and analyzed. RESULTS: From pre-RT to mid-RT, parotid volume decreased (atrophy rate, 27.0 ± 11.5%), while parotid T2 and FF values increased (change rate, 6.0 ± 6.2% for T2 value and 9.1 ± 9.9% for FF value) significantly. From mid-RT to post-RT, parotid T2 value continuously increased (change rate, 4.6 ± 7.7%), but parotid FF value decreased (change rate, - 9.9 ± 18.2%) significantly. Change rate of parotid T2 value significantly correlated with parotid atrophy rate from pre-RT to post-RT (r = 0.313, P = 0.027). Multiple linear regression analysis showed that parotid T2 value (standardized coefficient [SC] = - 0.259, P = 0.001) and FF value (SC = - 0.320, P = 0.014) negatively correlated with parotid volume, while parotid T2 value positively correlated with MR scan time point (SC = 0.476, P = 0.001) significantly. Parotid T2 and FF values showed excellent reproducibility (intraclass correlation coefficient, 0.935-0.992). CONCLUSIONS: T2 mapping and mDIXON Quant imaging is useful for noninvasive evaluation of radiation-induced parotid damage.
引用
- Zhou N, Chu C, Dou X, et al. Early evaluation of radiation-induced parotid damage in patients with nasopharyngeal carcinoma by T2 mapping and mDIXON Quant imaging: initial findings. Radiat Oncol. 2018. PMID: 29422068. doi:10.1186/s13014-018-0970-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。