文献速递中枢神经肿瘤放疗放疗物理与技术

短扩散时间振荡梯度扩散加权成像作为胶质母细胞瘤放疗反应监测的早期磁共振成像生物标志物:临床前可行性研究

Short Diffusion Time Diffusion-Weighted Imaging With Oscillating Gradient Preparation as an Early Magnetic Resonance Imaging Biomarker for Radiation Therapy Response Monitoring in Glioblastoma: A Preclinical Feasibility Study.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2018-01-04

该临床前研究在U87胶质母细胞瘤小鼠模型中比较了振荡梯度制备(OGSE)短有效扩散时间(Δeff=1.25 ms)扩散加权成像(DWI)与标准脉冲梯度DWI(PGSE,Δeff=18 ms)在放疗反应监测中的价值。结果显示OGSE图上肿瘤ADC较周围白质高30%-50%,与组织学相关性好,且在14 Gy放疗剂量后即可检测到肿瘤ADC约15%的显著升高,而PGSE未检测到显著放疗反应。

要点

  • OGSE短Δeff DWI较PGSE能更好区分肿瘤与白质,与组织学区域相关性好。
  • OGSE在14 Gy放疗剂量后即可检测到肿瘤ADC约15%的显著升高。
  • PGSE对放疗引起的微结构变化敏感性低,未检测到显著反应。

核心结论

  • 短Δeff OGSE DWI比常规PGSE DWI更能反映组织学定义的肿瘤区域,并能更一致、更早地检测放疗引起的微结构变化。

研究设计与样本

  • 使用自建cos-OGSE DWI序列(Δeff=1.25 ms)与标准PGSE DWI协议(Δeff=18 ms)在6个时间点进行ADC成像,采用重复测量方差分析和Sidak事后检验比较肿瘤与对侧白质的纵向ADC变化。

主要发现

  • 在短Δeff OGSE图上,肿瘤ADC通常比周围白质高30%-50%,且区域与组织学相关性好。
  • PGSE图上白质/肿瘤对比不显著,肿瘤识别通常更困难。
  • 放疗期间OGSE图显示肿瘤ADC显著升高(约15%),在14 Gy放疗剂量后一致可见。
  • 临床参考PGSE对放疗变化敏感性较低,在放疗组和时间进程中未检测到显著反应。

临床怎么用

  • OGSE短Δeff DWI有望作为稳健的微结构放疗反应生物标志物,帮助将重要治疗决策提前至放疗疗程更早阶段。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate a novel alternative diffusion-weighted imaging (DWI) approach using oscillating gradients preparation (OGSE) to obtain much shorter effective diffusion times (Δeff) for tumor response monitoring by apparent diffusion coefficient (ADC) mapping in a glioblastoma mouse model. METHODS AND MATERIALS: Twenty-four BALB/c nude mice inoculated with U87 glioblastoma cells were randomized into a control group and an irradiation group, which underwent a 15-day fractioned radiation therapy (RT) course with 2 Gy/d. Therapy response was assessed by mapping of ADCs at 6 time points using an in-house implementation of a cos-OGSE DWI sequence with Δeff = 1.25 ms and compared with a standard pulsed gradient DWI protocol (PGSE) with typical clinical diffusion time Δeff = 18 ms. Longitudinal ADC changes in tumor and contralateral white matter (WM) were statistically assessed using repeated-measures analysis of variance and post hoc (Sidak) testing. RESULTS: On short Δeff OGSE maps tumor ADC was generally 30%-50% higher than in surrounding WM. Areas correlated well with histology. Tumor identification was generally more difficult on PGSE maps owing to nonsignificant WM/tumor contrast. During RT, OGSE maps also showed significant tumor ADC increase (approximately 15%) in response to radiation, consistently seen after 14-Gy RT dose. The clinical reference (PGSE) showed lower sensitivity to radiation changes, and no significant response across the radiation group and time course could be detected. CONCLUSION: Our short Δeff DWI method using OGSE better reflected histologically defined tumor areas and enabled more consistent and earlier detection of microstructural radiation changes than conventional methods. Oscillating gradients preparation offers significant potential as a robust microstructural RT response biomarker, potentially helping to shift important therapy decisions to earlier stages in the RT time course.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Bongers A, Hau E, Shen H, et al. Short Diffusion Time Diffusion-Weighted Imaging With Oscillating Gradient Preparation as an Early Magnetic Resonance Imaging Biomarker for Radiation Therapy Response Monitoring in Glioblastoma: A Preclinical Feasibility Study. Int J Radiat Oncol Biol Phys. 2018. PMID: 29429801. doi:10.1016/j.ijrobp.2017.12.280

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。