文献速递胸部肿瘤放疗放疗物理与技术

一种整合3D与4D计划胸部放疗患者队列靶区数据用于机器学习的方法

A method to combine target volume data from 3D and 4D planned thoracic radiotherapy patient cohorts for machine learning applications.
PubMed 文献 · Radiother Oncol · 2017-12-06

该研究开发并验证了一种从iGTV合成GTV数据的方法,以便将3D和4D计划的肺癌患者队列合并用于机器学习建模。基于40例非小细胞肺癌患者的专家勾画,线性拟合与侵蚀法合成的GTV体积在观察者间勾画变异范围内,形状DSC均值上叶0.8817、下叶0.8584。联合真实与合成数据训练的随机森林模型显著优于仅用GTV或GTV联合iGTV的模型。

要点

  • 从iGTV合成GTV体积的误差在观察者间勾画变异范围内
  • 合成GTV形状与真实GTV的DSC均值上叶0.8817、下叶0.8584
  • 联合真实与合成数据训练的模型显著优于仅用GTV或GTV+iGTV

核心结论

  • 从iGTV可准确合成GTV大小,从而合并肺癌患者队列,促进胸部放疗的机器学习应用。

研究设计与样本

  • 研究纳入40例非小细胞肺癌患者的专家勾画数据,开发线性拟合与侵蚀法从iGTV合成GTV体积和形状。
  • 采用Dice相似系数(DSC)和最近点测量评估合成质量,并计算剂量学特征及构建随机森林模型比较。

主要发现

  • 合成GTV体积估计值在观察者间勾画变异幅度内。
  • 形状比较中,上叶病例平均DSC为0.8817,下叶病例为0.8584。
  • 在联合真实与合成数据上训练的模型显著优于仅用GTV或GTV联合iGTV数据训练的模型。

关键数值与推荐

  • 上叶病例合成GTV与真实GTV的平均DSC为0.8817。
  • 下叶病例合成GTV与真实GTV的平均DSC为0.8584。

临床怎么用

  • 可将3D计划与4D计划胸部放疗患者队列的靶区数据合并,扩大机器学习建模样本量。
  • 从iGTV合成GTV时需注意分叶位置,下叶形状一致性略低于上叶。

局限性

  • 研究仅基于40例非小细胞肺癌患者,样本量有限。
  • 合成方法基于专家勾画开发,未报告外部验证结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: The gross tumour volume (GTV) is predictive of clinical outcome and consequently features in many machine-learned models. 4D-planning, however, has prompted substitution of the GTV with the internal gross target volume (iGTV). We present and validate a method to synthesise GTV data from the iGTV, allowing the combination of 3D and 4D planned patient cohorts for modelling. MATERIAL AND METHODS: Expert delineations in 40 non-small cell lung cancer patients were used to develop linear fit and erosion methods to synthesise the GTV volume and shape. Quality was assessed using Dice Similarity Coefficients (DSC) and closest point measurements; by calculating dosimetric features; and by assessing the quality of random forest models built on patient populations with and without synthetic GTVs. RESULTS: Volume estimates were within the magnitudes of inter-observer delineation variability. Shape comparisons produced mean DSCs of 0.8817 and 0.8584 for upper and lower lobe cases, respectively. A model trained on combined true and synthetic data performed significantly better than models trained on GTV alone, or combined GTV and iGTV data. CONCLUSIONS: Accurate synthesis of GTV size from the iGTV permits the combination of lung cancer patient cohorts, facilitating machine learning applications in thoracic radiotherapy.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Johnson C, Price G, Khalifa J, et al. A method to combine target volume data from 3D and 4D planned thoracic radiotherapy patient cohorts for machine learning applications. Radiother Oncol. 2017. PMID: 29223683. doi:10.1016/j.radonc.2017.11.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。