Intensity-based dual model method for generation of synthetic CT images from standard T2-weighted MR images - Generalized technique for four different MR scanners.
PubMed 文献 · Radiother Oncol · 2017-10-30

本研究提出一种基于强度的泛化双模型HU转换方法,利用盆腔标准T2加权MRI生成合成CT(sCT),分别在图谱分割骨轮廓内外将MR信号转换为合成HU值。方法在20例与35例前列腺癌患者上开发与评估,影像来自3家厂商4台MR扫描仪;35例中软组织与骨组织HU平均(最大)差异分别为16±6(34)HU与-46±56(181)HU,PTV平均剂量差异平均为-0.6±0.4%(最大-1.3%),各扫描仪与序列剂量计算结果临床可接受。

要点

  • 标准T2w盆腔MRI可经双模型HU转换生成sCT。
  • 35例中PTV平均剂量差异平均-0.6±0.4%,最大-1.3%。
  • 方法在3厂商4台MR扫描仪及临床序列上结果临床可接受。

核心结论

  • 基于强度的双模型法可从盆腔标准T2w MRI生成sCT,并在纳入的各扫描仪与MR序列上获得临床可接受的剂量计算结果。

研究设计与样本

  • 方法开发使用20例前列腺癌患者,评估使用35例前列腺癌患者。
  • MR图像采用临床在用扫描序列,来自3家厂商的4台不同MR扫描仪。
  • 双模型HU转换在图谱分割骨体积轮廓内、外分别将T2w MR强度值转换为合成HU值。

主要发现

  • 35例前列腺癌患者sCT与真实CT相比,软组织体积HU差异平均16±6 HU、最大34 HU。
  • 骨组织体积HU差异平均-46±56 HU、最大181 HU。
  • sCT相对真实CT的PTV平均剂量差异平均-0.6±0.4%,最大-1.3%。

临床怎么用

  • 可将标准T2w盆腔MRI经该泛化方法生成sCT,用于仅基于MR的放疗治疗计划流程中的剂量计算。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Recent studies have shown that it is possible to conduct entire radiotherapy treatment planning (RTP) workflow using only MR images. This study aims to develop a generalized intensity-based method to generate synthetic CT (sCT) images from standard T2-weighted (T2w) MR images of the pelvis. MATERIALS AND METHODS: This study developed a generalized dual model HU conversion method to convert standard T2w MR image intensity values to synthetic HU values, separately inside and outside of atlas-segmented bone volume contour. The method was developed and evaluated with 20 and 35 prostate cancer patients, respectively. MR images with scanning sequences in clinical use were acquired with four different MR scanners of three vendors. RESULTS: For the generated synthetic CT (sCT) images of the 35 prostate patients, the mean (and maximal) HU differences in soft and bony tissue volumes were 16 ± 6 HUs (34 HUs) and -46 ± 56 HUs (181 HUs), respectively, against the true CT images. The average of the PTV mean dose difference in sCTs compared to those in true CTs was -0.6 ± 0.4% (-1.3%). CONCLUSIONS: The study provides a generalized method for sCT creation from standard T2w images of the pelvis. The method produced clinically acceptable dose calculation results for all the included scanners and MR sequences.

来源:Radiother Oncol,查看原文。版权归原作者所有。