影像引导频率对前列腺癌放疗PTV外扩及地理性脱靶的影响
该回顾性研究分析108例接受每日影像引导的前列腺癌患者共2700分次数据,模拟隔日、每周两次、每周一次、仅前3天及无影像引导5种方案。结果显示影像引导频率降低会增加系统误差,需更大PTV外扩;影像引导从50%降至12%时,7或5毫米PTV外扩下预测地理性脱靶分次比例逐渐增加,每减少15%影像引导估计增加5%地理性脱靶风险。
要点
- 减少影像引导频率会增加系统误差均值及标准差。
- 低于每日影像引导需更大的PTV外扩以保证临床靶区覆盖。
- 每减少15%影像引导估计增加5%地理性脱靶风险。
核心结论
- 对前列腺癌调强放疗患者,低于每日的影像引导需要更大的PTV外扩。
- 每减少15%影像引导频率,估计地理性脱靶风险增加5%。
研究设计与样本
- 回顾性分析108例连续前列腺癌患者共2700分次每日螺旋断层放疗影像引导的摆位误差与三维对准数据。
- 模拟隔日、每周两次、每周一次、仅前3天及无影像引导5种IGRT方案并建模确定各方案PTV外扩。
- 使用7毫米和5毫米两种常用PTV外扩分析各方案下各方向可能的地理性脱靶。
主要发现
- 降低影像引导频率会增加系统误差均值及系统误差标准差。
- 影像引导频率降低时,达到充分临床靶区覆盖所需PTV外扩增加。
- 影像引导从50%降至12%时,7或5毫米等向PTV外扩下预测地理性脱靶的分次百分比逐渐增加。
- 每减少15%影像引导,估计地理性脱靶风险增加5%。
临床怎么用
- 前列腺癌调强放疗采用低于每日IGRT时,应依据实际影像引导频率增大PTV外扩以维持靶区覆盖。
- 减少影像引导频率需权衡地理性脱靶风险增加与资源时间消耗。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The relationship between frequency of imaging during image guided radiation therapy (IGRT) and planning target volume (PTV) margin remains unclear. This issue is of practical significance given resource and time intensive nature of IGRT. The purpose of this study was to evaluate PTV margins with predefined and commonly used less-than-daily IGRT schedules using data obtained from patients treated with daily IGRT for prostate cancer. METHODS AND MATERIALS: Daily setup error and 3-dimensional daily alignment data for a total of 108 consecutive patients with prostate cancer treated with 2700 fractions of daily image guidance on tomotherapy were retrospectively analyzed. Five IGRT scenarios were simulated: alternate day, twice weekly, once weekly, first 3 days only, and no image guidance. The daily alignment data were modeled to simulate the 5 predefined scenarios by applying appropriate corrections to determine the PTV margin for each image guidance scenario. The data were also analyzed to predict possible geographical miss in any direction using 2 frequently used PTV margins of 7 and 5 mm for all the scenarios. RESULTS: Decreasing the frequency of image guidance increased the mean systematic error and the standard deviation of the systematic error. With decreased image guidance frequency, an increase in PTV margins was required to achieve adequate coverage of the clinical target volume. With reduction in image guidance from 50% to 12%, a gradual increase in percentage of fractions with predicted geographical miss using an isotropic PTV margin of 7 or 5 mm was seen. With every 15% decrease in imaging, a 5% increased risk of geographical miss was estimated. CONCLUSIONS: The use of less-than-daily IGRT requires larger PTV margins for patients treated with intensity modulated radiation therapy for prostate cancer. With every 15% reduction, a 5% increased risk of geographical miss was estimated.
引用
- Gupta M, Gamre P, Kannan S, et al. Effect of imaging frequency on PTV margins and geographical miss during image guided radiation therapy for prostate cancer. Pract Radiat Oncol. 2017. PMID: 29122556. doi:10.1016/j.prro.2017.09.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。