视听生物反馈引导屏气改善肺癌肿瘤位置重复性与体积一致性
本研究纳入9例肺癌患者,在两次MRI会话中比较传统屏气(CBH)与视听生物反馈屏气(AVBH)对分次间肿瘤位置重复性和分次内体积一致性的影响。结果显示AVBH使分次间GTV质心位置重复性改善46%(P=.009),分次内GTV一致性改善70%(P=.023)。
要点
- AVBH使分次间GTV质心位置重复性改善46%(P=.009)。
- AVBH使分次内GTV体积一致性改善70%(P=.023)。
- AVBH使GTV位置范围改善69%(P=.052)。
核心结论
- 视听生物反馈屏气可改善肺癌屏气时肿瘤位置重复性与体积一致性。
研究设计与样本
- 9例肺癌患者在接受2次MRI前进行AVBH屏气训练。
- 第一次MRI(治疗前)采集CBH与AVBH的吸气与呼气屏气三维MRI。
- 第二次MRI(治疗中)在第一次后6周内重复。
- 在每个数据集上勾画GTV。
- 比较CBH与AVBH的GTV质心位置、位置范围及吸气与呼气间GTV体积一致性。
主要发现
- 与CBH相比,AVBH使分次间GTV质心位置重复性改善46%(P=.009),从8.8 mm降至4.8 mm。
- 与CBH相比,AVBH使GTV位置范围改善69%(P=.052),从7.4 mm降至2.3 mm。
- 与CBH相比,AVBH使分次内GTV一致性改善70%(P=.023),从7.8 cm3降至2.5 cm3。
关键数值与推荐
- 分次间GTV质心位置重复性:AVBH较CBH改善46%(P=.009),从8.8 mm降至4.8 mm。
- GTV位置范围(吸气与呼气间GTV质心距离):AVBH较CBH改善69%(P=.052),从7.4 mm降至2.3 mm。
- 分次内GTV一致性(吸气与呼气间GTV):AVBH较CBH改善70%(P=.023),从7.8 cm3降至2.5 cm3。
临床怎么用
- AVBH可作为呼吸门控肺癌放疗中改善屏气时肿瘤位置重复性与体积一致性的屏气技术。
- 该结果可能为更精确的肺癌放疗及屏气操作下的医学成像与治疗提供路径。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Respiratory variation can increase the variability of tumor position and volume, accounting for larger treatment margins and longer treatment times. Audiovisual biofeedback as a breath-hold technique could be used to improve the reproducibility of lung tumor positions at inhalation and exhalation for the radiation therapy of mobile lung tumors. This study aimed to assess the impact of audiovisual biofeedback breath-hold (AVBH) on interfraction lung tumor position reproducibility and volume consistency for respiratory-gated lung cancer radiation therapy. METHODS: Lung tumor position and volume were investigated in 9 patients with lung cancer who underwent a breath-hold training session with AVBH before 2 magnetic resonance imaging (MRI) sessions. During the first MRI session (before treatment), inhalation and exhalation breath-hold 3-dimensional MRI scans with conventional breath-hold (CBH) using audio instructions alone and AVBH were acquired. The second MRI session (midtreatment) was repeated within 6 weeks after the first session. Gross tumor volumes (GTVs) were contoured on each dataset. CBH and AVBH were compared in terms of tumor position reproducibility as assessed by GTV centroid position and position range (defined as the distance of GTV centroid position between inhalation and exhalation) and tumor volume consistency as assessed by GTV between inhalation and exhalation. RESULTS: Compared with CBH, AVBH improved the reproducibility of interfraction GTV centroid position by 46% (P = .009) from 8.8 mm to 4.8 mm and GTV position range by 69% (P = .052) from 7.4 mm to 2.3 mm. Compared with CBH, AVBH also improved the consistency of intrafraction GTVs by 70% (P = .023) from 7.8 cm3 to 2.5 cm3. CONCLUSIONS: This study demonstrated that audiovisual biofeedback can be used to improve the reproducibility and consistency of breath-hold lung tumor position and volume, respectively. These results may provide a pathway to achieve more accurate lung cancer radiation treatment in addition to improving various medical imaging and treatments by using breath-hold procedures.