文献速递胸部肿瘤放疗放疗物理与技术

III期肺癌保留正常肺组织的螺旋断层放疗技术

Normal lung sparing Tomotherapy technique in stage III lung cancer.
PubMed 文献 · Radiat Oncol · 2017-11-06

结果表明螺旋断层调强放疗在靶区适形性、均匀性及降低肺低中剂量体积方面最优,肺正常组织并发症概率最低,但治疗时间较长。

要点

  • 螺旋断层调强放疗的靶区适形指数和均匀指数最佳(0.82和1.06)。
  • 螺旋断层调强放疗的肺平均剂量最低,且显著降低V5~30(对比静态调强)和V5~20(对比静态断层调强)。
  • 肺正常组织并发症概率螺旋断层调强最低(6.42%),其次静态断层调强(6.53%),静态调强最高(8.11%)。

核心结论

  • 基于完整和方向性阻断功能的束流角度优化可实现螺旋断层调强放疗的有利剂量学特征,有助于放射肿瘤医生为IIIB期非小细胞肺癌选择调强放疗方式。

主要发现

  • 螺旋断层调强放疗的靶区适形指数和均匀指数最佳(0.82和1.06),静态断层调强为0.81和1.07,静态调强为0.75和1.08。
  • 螺旋断层调强放疗的肺平均剂量最低,三种计划肺平均剂量均≤20 Gy。
  • 螺旋断层调强放疗较静态调强显著降低肺V5~30,较静态断层调强显著降低V5~20。
  • 静态断层调强在V20和V30方面显著优于静态调强,三种计划间V40无显著差异。
  • 肺正常组织并发症概率螺旋断层调强最低(6.42%),静态断层调强为6.53%,静态调强为8.11%;静态断层调强治疗时间最短,其次为静态调强。

临床怎么用

  • 对于IIIB期非小细胞肺癌,若需优化正常肺组织保护,可优先考虑基于束流角度优化的螺旋断层调强放疗。
  • 随着PTV长度增加,三种计划的肺正常组织并发症概率和肺平均剂量均显著增加,需关注长靶区患者的肺毒性风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Radiation pneumonitis (RP) has been a challenging obstacle in treating stage III lung cancer patients. Beam angle optimization (BAO) technique for Tomotherapy was developed to reduce the normal lung dose for stage III non-small cell lung cancer (NSCLC). Comparative analyses on plan quality by 3 different Intensity-modulated radiation therapy (IMRT) methods with BAO were done. MATERIALS AND METHODS: Ten consecutive stage IIIB NSCLC patients receiving linac-based static IMRT (L-IMRT) with total 66 Gy in 33 fractions to the PTV were selected. Two additional Tomotherapy-based IMRT plans (helical beam (TH-IMRT) and static beam (TD-IMRT)) were generated on each patient. To reduce the normal lung dose, Beam angles were optimized by using complete and directional block functions in Tomotherapy based on knowledge based statistical analysis. Plan quality was compared with target coverage, normal organ sparing capability, and normal tissue complication probability (NTCP). Actual beam delivery times and risk of RP related with planning target volume (PTV) were also evaluated. RESULTS: The best PTV coverage measured by conformity index and homogeneity index was achievable by TH-IMRT (0.82 and 1.06), followed by TD-IMRT (0.81 and 1.07) and L-IMRT (0.75 and 1.08). Mean lung dose was the lowest in TH-IMRT plan followed by TD-IMRT and L-IMRT, all of which were ≤20 Gy. TH-IMRT plan could significantly lower the lung volumes receiving low to medium dose levels: V5~30 when compared to L-IMRT plan; and V5~20 when compared to TD-IMRT plan, respectively. TD-IMRT plan was significantly better than L-IMRT with respects to V20 and V30 and there was no significant difference with respect to V40 among three plans. The NTCP of the lung was the lowest in TH-IMRT plan, followed by TD-IMRT and L-IMRT (6.42% vs. 6.53% vs. 8.11%). Beam delivery time was the shortest in TD-IMRT plan followed by L-IMRT. As PTV length increased, NTCP and Mean lung dose proportionally increased significantly in all three plans. CONCLUSION: Advantageous profiles by TH-IMRT could be achieved by BAO by complete and directional block functions. Current observation could help radiation oncologists to make wise selection of IMRT method for stage IIIB NSCLC.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Hong CS, Ju SG, Ahn YC, et al. Normal lung sparing Tomotherapy technique in stage III lung cancer. Radiat Oncol. 2017. PMID: 29110732. doi:10.1186/s13014-017-0905-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。