文献速递头颈部肿瘤放疗放疗物理与技术

头颈部放疗多模态变形配准的无参考局部误差自动评估

Automated, reference-free local error assessment of multimodal deformable image registration for radiotherapy in the head and neck.
PubMed 文献 · Radiother Oncol · 2017-10-31

本研究评估基于局部刚性再配准的无参考误差评估算法(b-MI与b-pmMI),用于头颈部MR-CT变形图像配准(DIR)的逐患者精度评估。结果表明两种算法能准确检测1-4 mm旋转平移误差及5 mm以内平移误差,b-pmMI在低对比度或CT伪影区域更稳定且速度提升10倍。

要点

  • b-MI与b-pmMI可无参考地定量评估头颈部MR-CT DIR的局部误差。
  • 两种算法能准确检测1-4 mm的旋转平移误差及5 mm以内的平移误差。
  • b-pmMI在低对比度或CT伪影区域更稳定,且速度比b-MI快10倍。

核心结论

  • b-MI和b-pmMI算法经验证可提供逐患者的无参考DIR精度定量评估。
  • b-pmMI在存在模态特异性信息时更快且更稳健。

研究设计与样本

  • 头颈部MR(治疗位与非治疗位)与计划CT进行DIR,基于原生及伪模态图像的局部刚性再配准开发无参考误差评估算法。
  • b-MI与b-pmMI算法针对施加的旋转和平移进行验证,并在14例患者数据集中比较内在配准误差检测。

主要发现

  • 治疗位MR-CT DIR中,两种算法均能准确确定1至4 mm的旋转平移误差。
  • 诊断位MR-CT DIR中,两种方法均能在大体肿瘤体积内准确检测 up to 5 mm的平移。
  • 14例患者数据集中,b-MI与b-pmMI检测相似误差,b-pmMI在低对比度或CT伪影区域稳定性改善且速度提升10倍。

临床怎么用

  • b-MI与b-pmMI可用于头颈部MR-CT DIR的逐患者无参考精度评估。
  • b-pmMI因速度更快且对模态特异性信息更稳健,可能更适合临床工作流。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Head and neck MR-CT deformable image registration (DIR) for radiotherapy planning is hindered by the lack of both ground-truth and per-patient accuracy assessment methods. This study assesses novel post-registration reference-free error assessment algorithms, based on local rigid re-registration of native and pseudomodality images. METHODS: Head and neck MR obtained in and out of the treatment position underwent DIR to planning CT. Block-wise mutual information (b-MI) and pseudomodality mutual information (b-pmMI) algorithms were validated against applied rotations and translations. Inherent registration error detection was compared across 14 patient datasets. RESULTS: Using radiotherapy position MR-CT DIR, quantitative comparison of applied rotations and translations revealed that errors between 1 and 4 mm were accurately determined by both algorithms. Using diagnostic position MR-CT DIR, translations of up to 5 mm were accurately detected within the gross tumour volume by both methods. In 14 patient datasets, b-MI and b-pmMI detected similar errors with improved stability in regions of low contrast or CT artefact and a 10-fold speedup for b-pmMI. CONCLUSIONS: b-MI and b-pmMI algorithms have been validated as providing accurate reference-free quantitative assessment of DIR accuracy on a per-patient basis. b-pmMI is faster and more robust in the presence of modality-specific information.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Nix MG, Prestwich RJD, Speight R, et al. Automated, reference-free local error assessment of multimodal deformable image registration for radiotherapy in the head and neck. Radiother Oncol. 2017. PMID: 29100697. doi:10.1016/j.radonc.2017.10.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。