文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

局部晚期宫颈癌在线自适应放疗中计划库最优计划数研究

What is the optimal number of library plans in ART for locally advanced cervical cancer?
PubMed 文献 · Radiother Oncol · 2017-09-19

本研究基于14例接受治疗的局部晚期宫颈癌患者数据,构建包含1-4个VMAT计划的计划库,以子宫运动幅度(HD99)分层评估剂量学获益。结果显示HD99与OAR保护体积呈中至强相关,所有患者从增加第2个计划中获益;HD99在30-50mm的患者使用3计划库较2计划库使复合V40Gy降低11-21ml。结论提示HD99>30mm的患者可从扩展至3个计划中获益,HD99可作为治疗前筛选标准。

要点

  • 所有患者从2计划库中获益,与当前临床实践一致。
  • HD99在30-50mm的患者,3计划库较2计划库复合V40Gy降低11-21ml。
  • HD99>30mm可作为治疗前筛选扩展计划库患者的简易标准。

核心结论

  • 子宫运动幅度大(HD99>30mm)的局部晚期宫颈癌患者可从计划库扩展至3个计划中获益。
  • HD99是治疗前筛选适合扩展计划库患者的简易标准。

研究设计与样本

  • 研究分析了14例已治疗局部晚期宫颈癌患者的数据,构建包含1-4个VMAT计划的计划库。
  • 以Hausdorff距离第99百分位数(HD99)定义治疗前子宫运动幅度。
  • 在每日CBCT扫描上勾画OAR,模拟计划选择并记录V45Gy和V40Gy参数。

主要发现

  • HD99与OAR保护体积之间呈中至强相关。
  • 所有患者从增加第2个计划中获益。
  • HD99在30-50mm的患者,3计划库较2计划库使复合V40Gy降低11-21ml。

关键数值与推荐

  • HD99>30mm作为筛选可从3计划库获益患者的治疗前标准。
  • 剂量学评估参数包括V45Gy和V40Gy。

临床怎么用

  • 治疗前测量HD99,对HD99>30mm的局部晚期宫颈癌患者可将计划库扩展至3个计划以改善OAR保护。
  • HD99≤30mm的患者维持2计划库即可,因所有患者已从第2个计划中获益。

局限性

  • 研究仅纳入14例患者,样本量较小。
  • 原文未报告剂量学获益的统计显著性检验结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Library-of-plans ART is used to manage daily anatomy changes in locally advanced cervical cancer. In our institute, the library contains 2 VMAT plans for patients with large cervix-uterus motion. Increasing this number could be beneficial for tissue sparing, but is burdensome while the dosimetric gain is yet unclear. This study's aim is to determine the optimal number of plans at an individual patient level. MATERIAL AND METHODS: Data of 14 treated patients were analyzed. Plan libraries were created containing 1-4 VMAT plans. Pre-treatment extent of uterus motion was defined by the 99th percentile of the Hausdorff distance (HD99). For dosimetric evaluations, OARs were contoured in daily CBCT scans, plan selection was simulated, and the V45Gy and V40Gy parameters were recorded. RESULTS: Moderate to strong correlations were found between HD99 and the volume of spared OARs. All patients benefitted from adding a 2nd plan, as is the clinical practice. For patients with a HD99 between 30 and 50mm, a 3-plan library reduced the composite V40Gy with 11-21ml compared to a 2-plan library. CONCLUSION: Patients with large uterus motion (HD99>30mm) would benefit from an extension of the plan library to 3. HD99 is an easy-to-implement criteria to select those patients pre-treatment.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Nováková E, Heijkoop ST, Quint S, et al. What is the optimal number of library plans in ART for locally advanced cervical cancer? Radiother Oncol. 2017. PMID: 28939180. doi:10.1016/j.radonc.2017.08.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。