双能CT评估肺功能在放疗计划中的1-2期研究
DECT与SPECT/CT肺叶功能强相关(r=0.89,P<.00001)。将功能图整合入放疗计划后,功能肺与解剖肺的V5和平均剂量差异显著(P=.03和P=.047)。
要点
- DECT碘图衍生的肺叶功能与SPECT/CT强相关(r=0.89)。
- 功能肺与解剖肺的V5平均差异16%(P=.03),MLD差异15%(P=.047)。
- V20差异5%(P=.12)无统计学意义。
核心结论
- DECT碘图衍生的肺叶功能与SPECT/CT相关性好,整合入肺癌放疗计划后功能肺的V5和MLD与解剖肺存在显著差异。
主要发现
- DECT与SPECT/CT肺叶功能Pearson相关系数r=0.89(P<.00001)。
- 功能肺与解剖肺V5平均差异16%(范围0%-48%,P=.03),V20差异5%(1%-15%,P=.12),MLD差异15%(1%-43%,P=.047)。
临床怎么用
- 可利用DECT碘图评估肺叶功能并整合至放疗计划系统,比较功能肺与解剖肺的剂量参数以优化肺保护。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To quantify lung function according to a dual-energy computed tomography (DECT)-derived iodine map in patients treated with radiation therapy for lung cancer, and to assess the dosimetric impact of its integration in radiation therapy planning. METHODS AND MATERIALS: Patients treated with stereotactic ablative radiation therapy for early-stage or intensity modulated radiation therapy for locally advanced lung cancer were prospectively enrolled in this study. A DECT in treatment position was obtained at time of treatment planning. The relative contribution of each voxel to the total lung function was based on iodine distribution. The composition of each voxel was determined on the basis of a 2-material decomposition. The DECT-derived lobar function was compared with single photon emission computed tomography/computed tomography (SPECT/CT). A functional map was integrated in the treatment planning system using 6 subvolumes of increasing iodine distribution levels. Percent lung volume receiving 5 Gy (V5), V20, and mean dose (MLD) to whole lungs (anatomic) versus functional lungs were compared. RESULTS: Twenty-five patients with lung cancer, including 18 patients treated with stereotactic ablative radiation therapy and 7 patients with intensity modulated radiation therapy (locally advanced), were included. Eighty-four percent had chronic obstructive pulmonary disease. Median (range) forced expiratory volume in 1 second was 62% of predicted (29%-113%), and median diffusing capacity of the lung for carbon monoxide was 56% (39%-91%). There was a strong linear correlation between DECT- and SPECT/CT-derived lobar function (Pearson coefficient correlation r=0.89, P<.00001). Mean (range) differences in V5, V20, and MLD between anatomic and functional lung volumes were 16% (0%-48%, P=.03), 5% (1%-15%, P=.12), and 15% (1%-43%, P=.047), respectively. CONCLUSIONS: Lobar function derived from a DECT iodine map correlates well with SPECT/CT, and its integration in lung treatment planning is associated with significant differences in V5 and MLD to functional lungs. Future work will involve integration of the weighted functional volume in the treatment planning system, along with integration of an iodine map for functional lung-sparing IMRT.
引用
- Bahig H, Campeau MP, Lapointe A, et al. Phase 1-2 Study of Dual-Energy Computed Tomography for Assessment of Pulmonary Function in Radiation Therapy Planning. Int J Radiat Oncol Biol Phys. 2017. PMID: 28871983. doi:10.1016/j.ijrobp.2017.05.051
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。