评估CT通气功能规避放疗的毒性降低效果
功能规避计划使≥2级和≥3级肺炎NTCP绝对降低分别达6.3%和3.6%(基于fV20Gy等指标),个体最大降低达52.3%和16.4%。
要点
- CT通气功能规避计划可降低功能性肺的剂量,从而降低放射性肺炎风险。
- 基于平均剂量-功能指标,≥2级和≥3级肺炎NTCP分别降低7.1%和4.7%。
- 个体患者最大NTCP降低可达52.3%(≥2级)和16.4%(≥3级)。
核心结论
- CT通气功能规避计划可量化降低≥2级和≥3级放射性肺炎的发生概率。
研究设计与样本
- 采用最大似然法建立NTCP模型,预测≥2级和≥3级肺炎与功能性肺剂量指标(fV5Gy、fV10Gy、fV20Gy、fV30Gy、平均剂量)的关系。
- 对30例患者生成功能规避计划,目标为降低功能性肺剂量并满足RTOG 0617约束,比较功能计划与临床计划的NTCP。
主要发现
- 基于fV20Gy、fV30Gy和功能性肺平均剂量,≥2级肺炎NTCP绝对降低分别为6.3%、7.8%和4.8%。
- 基于fV20Gy、fV30Gy和功能性肺平均剂量,≥3级肺炎NTCP绝对降低分别为3.6%、4.8%和2.4%。
- 个体患者中,≥2级和≥3级肺炎最大绝对降低分别为52.3%和16.4%。
- 基于平均剂量-功能指标,≥2级和≥3级肺炎降低分别为7.1%和4.7%。
关键数值与推荐
- 功能规避计划需满足RTOG 0617约束。
- NTCP模型预测≥2级和≥3级肺炎基于功能性肺的V5 Gy、V10 Gy、V20 Gy、V30 Gy和平均剂量。
临床怎么用
- 在胸部肿瘤放疗计划中可考虑整合CT通气功能规避,以降低功能性肺剂量并潜在减少放射性肺炎。
- 功能规避计划应在满足RTOG 0617约束的前提下进行优化。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Computed tomographic (CT) ventilation imaging is a new modality that uses 4-dimensional (4D) CT information to calculate lung ventilation. Although retrospective studies have reported on the reduction in dose to functional lung, no work to our knowledge has been published in which the dosimetric improvements have been translated to a reduction in the probability of pulmonary toxicity. Our work estimates the reduction in toxicity for CT ventilation-based functional avoidance planning. METHODS AND MATERIALS: Seventy previously treated lung cancer patients who underwent 4DCT imaging were used for the study. CT ventilation maps were calculated with 4DCT deformable image registration and a density change-based algorithm. Pneumonitis was graded on the basis of imaging and clinical presentation. Maximum likelihood methods were used to generate normal tissue complication probability (NTCP) models predicting grade 2 or higher (2+) and grade 3+ pneumonitis as a function of dose (V5 Gy, V10 Gy, V20 Gy, V30 Gy, and mean dose) to functional lung. For 30 patients a functional plan was generated with the goal of reducing dose to the functional lung while meeting Radiation Therapy Oncology Group 0617 constraints. The NTCP models were applied to the functional plans and the clinically used plans to calculate toxicity reduction. RESULTS: By the use of functional avoidance planning, absolute reductions in grade 2+ NTCP of 6.3%, 7.8%, and 4.8% were achieved based on the mean fV20 Gy, fV30 Gy, and mean dose to functional lung metrics, respectively. Absolute grade 3+ NTCP reductions of 3.6%, 4.8%, and 2.4% were achieved with fV20 Gy, fV30 Gy, and mean dose to functional lung. Maximum absolute reductions of 52.3% and 16.4% were seen for grade 2+ and grade 3+ pneumonitis for individual patients. CONCLUSION: Our study quantifies the possible toxicity reduction from CT ventilation-based functional avoidance planning. Reductions in grades 2+ and 3+ pneumonitis were 7.1% and 4.7% based on mean dose-function metrics, with reductions as high as 52.3% for individual patients. Our work provides seminal data for determining the potential toxicity benefit from incorporating CT ventilation into thoracic treatment planning.
引用
- Faught AM, Miyasaka Y, Kadoya N, et al. Evaluating the Toxicity Reduction With Computed Tomographic Ventilation Functional Avoidance Radiation Therapy. Int J Radiat Oncol Biol Phys. 2017. PMID: 28871982. doi:10.1016/j.ijrobp.2017.04.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。