文献速递头颈部肿瘤放疗放疗物理与技术

鼻咽癌局部复发与半导体探测器PET的FMISO摄取基于体素分析

Local relapse of nasopharyngeal cancer and Voxel-based analysis of FMISO uptake using PET with semiconductor detectors.
PubMed 文献 · Radiat Oncol · 2017-09-06

本研究纳入9例IMRT后局部复发和12例无复发的鼻咽癌患者,用半导体探测器FMISO-PET在放疗前进行基于体素分析,发现复发区域FMISO摄取显著高于非复发区域,但预测价值不足以支持对瘤内高摄取区 upfront 剂量提升。

要点

  • 复发区域放疗前FMISO摄取显著高于非复发区域
  • FMISO-PET预测复发区域的价值有限(AUC低)
  • 不支持基于FMISO高摄取区进行 upfront 剂量提升

核心结论

  • 复发区域FMISO摄取显著高于非复发区域,但放疗前FMISO-PET预测价值不足以支持对瘤内高摄取区进行 upfront 剂量提升。

研究设计与样本

  • 纳入9例IMRT后局部复发和12例无局部复发超过3年的鼻咽癌患者,放疗前进行FMISO-PET,采用基于体素分析评估FMISO摄取与复发区域的关系。

主要发现

  • 放疗前FMISO-PET中,肿瘤复发区域体素的肿瘤与肌肉比值(TMR)显著高于非复发区域(p < 0.0001)。
  • 复发患者组中,TMR值1.37(95% CI: 1.36-1.39)对应复发率30%,比值比5.18(4.87-5.51),ROC曲线下面积(AUC)为0.613。
  • 全部21例患者中,TMR值2.42(2.36-2.49)对应估计复发率30%,AUC仅为0.591。

临床怎么用

  • 放疗前FMISO-PET显示复发区域摄取较高,但预测价值有限,暂不支持据此对瘤内高摄取区进行 upfront 剂量提升。

局限性

  • 样本量小(共21例),预测价值有限(AUC低),需要新的缺氧显像方法提高敏感性和特异性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Hypoxic cancer cells are thought to be radioresistant and could impact local recurrence after radiotherapy (RT). One of the major hypoxic imaging modalities is [18F]fluoromisonidazole positron emission tomography (FMISO-PET). High FMISO uptake before RT could indicate radioresistant sites and might be associated with future local recurrence. The predictive value of FMISO-PET for intra-tumoral recurrence regions was evaluated using high-resolution semiconductor detectors in patients with nasopharyngeal carcinoma after intensity-modulated radiotherapy (IMRT). METHODS: Nine patients with local recurrence and 12 patients without local recurrence for more than 3 years were included in this study. These patients received homogeneous and standard doses of radiation to the primary tumor irrespective of FMISO uptake. The FMISO-PET image before RT was examined via a voxel-based analysis, which focused on the relationship between the degree of FMISO uptake and recurrence region. RESULTS: In the pretreatment FMISO-PET images, the tumor-to-muscle ratio (TMR) of FMISO in the voxels of the tumor recurrence region was significantly higher than that of the non-recurrence region (p < 0.0001). In the recurrent patient group, a TMR value of 1.37 (95% CI: 1.36-1.39) corresponded to a recurrence rate of 30%, the odds ratio was 5.18 (4.87-5.51), and the area under the curve (AUC) of the receiver operating characteristic curve was 0.613. In all 21 patients, a TMR value of 2.42 (2.36-2.49) corresponded to an estimated recurrence rate of 30%, and the AUC was only 0.591. CONCLUSIONS: The uptake of FMISO in the recurrent region was significantly higher than that in the non-recurrent region. However, the predictive value of FMISO-PET before IMRT is not sufficient for up-front dose escalation for the intra-tumoral high-uptake region of FMISO. Because of the higher mean TMR of the recurrence region, a new hypoxic imaging method is needed to improve the sensitivity and specificity for hypoxia.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Nishikawa Y, Yasuda K, Okamoto S, et al. Local relapse of nasopharyngeal cancer and Voxel-based analysis of FMISO uptake using PET with semiconductor detectors. Radiat Oncol. 2017. PMID: 28877734. doi:10.1186/s13014-017-0886-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。