文献速递乳腺癌放疗放疗物理与技术

深吸气屏气用于需内乳淋巴结放疗且心脏解剖不利的左乳腺癌患者

Deep inspiration breathhold for left-sided breast cancer patients with unfavorable cardiac anatomy requiring internal mammary nodal irradiation.
PubMed 文献 · Pract Radiat Oncol · 2017-04-13

本研究评估适度深吸气屏气(mDIBH)在心脏解剖不利且需内乳淋巴结放疗的左乳腺癌患者中降低心脏受量的效用。以最大心脏距离(MHD)>1 cm 作为心脏解剖不利的替代指标,22 例患者接受自由呼吸(FB)与 mDIBH 模拟定位及计划设计,比较三维部分宽切线(3D-PWT)与调强放疗计划的心脏和肺剂量学参数。结果显示 mDIBH 显著降低平均心脏剂量(222.7 vs 578.4 cGy;P < .0001)及左肺 V20(31.93 vs 38.41%;P = .0006),且屏气后 MHD 变化可可靠预测平均心脏剂量下降。

要点

  • mDIBH 显著降低需内乳淋巴结放疗且心脏解剖不利患者的平均心脏剂量。
  • mDIBH 同时显著降低左肺 V20,且在 3D-PWT 与调强计划中均一致。
  • 屏气后 MHD 变化可可靠预测平均心脏剂量下降,治疗 delivery 约 11.31 分钟。

核心结论

  • mDIBH 高效且可有效降低需内乳淋巴结放疗且心脏解剖不利患者的平均心脏剂量,简化计划与实施。
  • 平均心脏剂量下降与最大心脏距离下降成比例。

研究设计与样本

  • 单中心研究,纳入 22 例需内乳淋巴结放疗且心脏解剖不利(MHD >1 cm)的左乳腺癌患者。
  • 患者接受自由呼吸与 mDIBH 计算机断层扫描模拟及计划设计,生成 3D-PWT 与调强放疗计划。
  • 采用剂量体积直方图比较心脏和肺剂量学参数,并记录所有分次治疗实施时间。

主要发现

  • mDIBH 扫描中 MHD 显著下降。
  • mDIBH 显著降低平均心脏剂量(222.7 vs 578.4 cGy;P < .0001)。
  • mDIBH 显著降低左肺 V20(31.93 vs 38.41%;P = .0006),在 3D-PWT 与调强放疗计划中均一致。
  • 屏气后 MHD 变化可可靠预测 mDIBH 后平均心脏剂量下降。
  • 放疗有效实施时间为 11.31 ± 3.40 分钟,每分次平均屏气 10.06 ± 2.74 次。

关键数值与推荐

  • 以 MHD >1 cm 作为心脏解剖不利的替代指标。
  • mDIBH 下平均心脏剂量 222.7 cGy 对比自由呼吸 578.4 cGy(P < .0001)。
  • mDIBH 下左肺 V20 31.93% 对比自由呼吸 38.41%(P = .0006)。

临床怎么用

  • 对需内乳淋巴结放疗且心脏解剖不利的左乳腺癌患者,可考虑采用 mDIBH 以降低心脏和左肺剂量。
  • 屏气后 MHD 变化可用于预测平均心脏剂量下降程度,辅助计划评估。
  • mDIBH 治疗实施时间约 11.31 分钟,每分次平均屏气约 10 次,具有操作可行性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to evaluate the utility of moderate deep inspiration breathhold (mDIBH) in reducing heart exposure in left breast cancer patients who have unfavorable cardiac anatomy and need internal mammary lymph node (IMLN) radiation therapy (RT). METHODS AND MATERIALS: We used maximum heart distance (MHD), defined as the maximum distance of the heart within the treatment field, >1 cm as a surrogate for unfavorable cardiac anatomy. Twenty-two left breast cancer patients with unfavorable cardiac anatomy requiring IMLN-RT underwent free-breathing (FB) and mDIBH computed tomography simulation and planning. Three-dimensional partially wide tangents (3D-PWTs) and intensity modulated RT plans were generated. Dose-volume histograms were used to compare heart and lung dosimetric parameters. Duration of treatment delivery was recorded for all fractions. RESULTS: MHD decreased significantly in mDIBH scans. mDIBH significantly reduced mean heart dose (222.7 vs 578.4 cGy; P < .0001) and percentage of left lung receiving doses ≥20 Gy (V20; 31.93 vs 38.41%; P = .0006) in both 3D-PWT and intensity modulated RT plans. The change in MHD after breathhold reliably predicted mean heart dose reduction after mDIBH. Radiation was effectively delivered in 11.31 ± 3.40 minutes with an average of 10.06 ± 2.74 breathholds per fraction. CONCLUSIONS: mDIBH is efficient and can effectively decrease mean heart dose in patients with unfavorable cardiac anatomy who need IMLN-RT, thus simplifying planning and delivery for them. The reduction in mean heart dose is proportional to the reduction in maximum heart distance.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Mohamad O, Shiao J, Zhao B, et al. Deep inspiration breathhold for left-sided breast cancer patients with unfavorable cardiac anatomy requiring internal mammary nodal irradiation. Pract Radiat Oncol. 2017. PMID: 28666899. doi:10.1016/j.prro.2017.04.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。