前列腺永久性近距离治疗中链状碘-125粒子位移模式:手术室剂量学的再审视

Displacement patterns of stranded I-125 seeds after permanent brachytherapy of the prostate: Dosimetry in the operating room put into perspective.
PubMed 文献 · Radiother Oncol · 2017-06-17

该研究对比33例链状粒子植入患者术中超声与术后1个月CT/MR配准的粒子几何与剂量分布,发现腹侧粒子显著向尾侧位移3.8±2.5mm,腹侧颅侧粒子位移大于尾侧粒子,腹侧颅侧区D90下降17±31Gy,提示术中剂量学需考虑粒子位移与前列腺萎缩的影响。

要点

  • 链状粒子植入后腹侧粒子向尾侧显著位移3.8±2.5mm。
  • 腹侧颅侧粒子位移4.5±2.7mm,大于尾侧粒子的2.9±2.6mm。
  • 腹侧颅侧区D90下降17±31Gy,背尾侧与腹尾侧区D90分别增加44±20Gy与29±28Gy。

核心结论

  • 链状粒子植入术后1个月剂量分布发生显著变化,主要归因于植入物与前列腺萎缩及腹侧粒子链向尾侧位移。

研究设计与样本

  • 对33例链状粒子植入患者,比较术中超声与术后1个月配准CT/MR的粒子几何与剂量分布。

主要发现

  • 腹侧粒子向尾侧位移3.8±2.5mm(p<0.001)。
  • 腹侧颅侧粒子位移4.5±2.7mm,腹侧尾侧粒子位移2.9±2.6mm(p<0.001)。
  • 背尾侧区D90增加44±20Gy(p<0.001),腹尾侧区D90增加29±28Gy(p<0.001)。
  • 腹颅侧区D90下降17±31Gy(p=0.008)。

临床怎么用

  • 使用链状粒子行术中或动态剂量学时,需考虑腹侧粒子向尾侧位移及前列腺萎缩对剂量分布的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: The reliability of post-implant dosimetry in the OR depends on the geometrical variability of implant and anatomy after the procedure. The purpose was to gain detailed information on seed displacement patterns in different sectors of the prostate. MATERIALS AND METHODS: Of 33 patients with stranded seed implants the seed geometry and the dose distribution were compared between the situation in the OR just after the procedure, based on ultrasound images, and the situation after 1month, based on registered CT and MR images. RESULTS: There was a substantial displacement of ventral seeds of 3.8±2.5mm in caudal direction (p<0.001). Of these ventral seeds cranially located seeds moved more than caudally located seeds, 4.5±2.7mm and 2.9±2.6mm, respectively (p<0.001). The D90 in the dorsal-caudal and ventral-caudal sectors increased with respectively 44±20Gy and 29±28Gy (p<0.001) and decreased with 17±31Gy in the ventral-cranial sector (p=0.008). CONCLUSIONS: There were substantial changes in dose distribution 1month after the procedure, mainly due to implant and prostate shrinkage and displacement of ventral seed strands in caudal direction. When performing dynamic dosimetry or dosimetry at the end of the procedure the effect of these phenomena has to be taken into account when using stranded seeds.