文献速递胸部肿瘤放疗放疗物理与技术

基于4D剂量计算比较呼吸运动管理技术:ITV、MidV、门控与床追踪

ITV, mid-ventilation, gating or couch tracking - A comparison of respiratory motion-management techniques based on 4D dose calculations.
PubMed 文献 · Radiother Oncol · 2017-06-03

结果显示单相追踪患侧肺Dmean最低(中位数3.3Gy),ITV最高(4.8Gy);MidV和单相追踪高估靶区平均剂量(-2.3%和-1.3%),其余技术轻微低估(<+1%)。ITV保证肿瘤覆盖但肺受量更高,MidV、门控和追踪可降低肺剂量。

要点

  • 单相追踪患侧肺Dmean中位数3.3Gy,为各技术中最低。
  • ITV概念保证肿瘤覆盖,但患侧肺Dmean中位数达4.8Gy。
  • MidV和单相追踪高估靶区平均剂量(-2.3%和-1.3%)。

核心结论

  • ITV概念确保肿瘤覆盖,但使肺组织受到更高剂量。
  • MidV、门控和追踪概念可降低肺剂量。
  • 追踪靶区定义中忽略肿瘤非平移变化会轻微降低靶区覆盖。
  • 临床应用MidV时应考虑其剂量覆盖稍差。

研究设计与样本

  • 基于4D-CT数据集和可变形图像配准进行4D剂量计算。
  • PTV根据各运动管理技术调整,立体定向放疗以65%等剂量线包绕PTV。
  • 追踪考虑三种靶区定义:单相追踪、多相追踪和可靠床追踪(含追踪延迟)。

主要发现

  • 单相追踪患侧肺Dmean中位数最低(3.3Gy),依次为多相追踪3.6Gy、门控3.8Gy、可靠床追踪4.1Gy、MidV 4.3Gy、ITV 4.8Gy。
  • 4D剂量计算显示MidV和单相追踪高估靶区平均剂量(分别为-2.3%和-1.3%)。
  • 其余运动管理技术轻微低估靶区平均剂量(<+1%)。

临床怎么用

  • 若优先降低肺剂量,可考虑单相追踪、多相追踪、门控或床追踪等技术。
  • 使用MidV时需注意其靶区剂量覆盖稍差。
  • 床追踪靶区定义应纳入肿瘤非平移变化和追踪延迟以避免覆盖不足。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Respiratory motion-management techniques (MMT) aim to ensure tumor dose coverage while sparing lung tissue. Dynamic treatment-couch tracking of the moving tumor is a promising new MMT and was compared to the internal-target-volume (ITV) concept, the mid-ventilation (MidV) principle and the gating approach in a planning study based on 4D dose calculations. METHODS: For twenty patients with lung lesions, planning target volumes (PTV) were adapted to the MMT and stereotactic body radiotherapy treatments were prepared with the 65%-isodose enclosing the PTV. For tracking, three concepts for target volume definition were considered: Including the gross tumor volume of one phase (single-phase tracking), including deformations between phases (multi-phase tracking) and additionally including tracking latencies of a couch tracking system (reliable couch tracking). The accumulated tumor and lung doses were estimated with 4D dose calculations based on 4D-CT datasets and deformable image registration. RESULTS: Single-phase tracking showed the lowest ipsilateral lung Dmean (median: 3.3Gy), followed by multi-phase tracking, gating, reliable couch tracking, MidV and ITV concepts (3.6, 3.8, 4.1, 4.3 and 4.8Gy). The 4D dose calculations showed the MidV and single-phase tracking overestimated the target mean dose (-2.3% and -1.3%), while it was slightly underestimated by the other MMT (<+1%). CONCLUSION: The ITV concept ensures tumor coverage, but exposes the lung tissue to a higher dose. The MidV, gating and tracking concepts were shown to reduce the lung dose. Neglecting non-translational changes of the tumor in the target volume definition for tracking results in a slightly reduced target coverage. The slightly inferior dose coverage for MidV should be considered when applying this technique clinically.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Ehrbar S, Jöhl A, Tartas A, et al. ITV, mid-ventilation, gating or couch tracking - A comparison of respiratory motion-management techniques based on 4D dose calculations. Radiother Oncol. 2017. PMID: 28587761. doi:10.1016/j.radonc.2017.05.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。