基于金标与四维锥形束CT量化呼吸诱发食管肿瘤运动的分次间变异性
结果显示振幅和轨迹形状的分次间变异性有限(平均≤1.4mm),4D-CT与4D-CBCT振幅平均绝对差≤1.0mm,提示单次4D-CT足以预测治疗疗程中的呼吸诱发食管肿瘤运动。
要点
- 呼吸诱发食管肿瘤运动振幅在远端食管头脚方向(平均7.1mm)和近端胃(平均7.8mm)最大。
- 治疗疗程中振幅无时间趋势,振幅和轨迹形状的分次间变异性有限(平均≤1.4mm)。
- 4D-CT与4D-CBCT量化的振幅差异小且无统计学意义(平均绝对差≤1.0mm)。
核心结论
- 振幅和轨迹形状的分次间变异性有限,且4D-CT与4D-CBCT振幅差异小,提示单次4D-CT足以预测治疗疗程中呼吸诱发食管肿瘤运动。
主要发现
- 振幅在远端食管头脚方向平均7.1mm,近端胃平均7.8mm。
- 治疗疗程中振幅无时间趋势,振幅和轨迹形状的分次间变异性平均≤1.4mm。
- 4D-CT与4D-CBCT振幅平均绝对差≤1.0mm,差异小且无统计学意义。
临床怎么用
- 基于单次4D-CT制定的呼吸诱发食管肿瘤运动范围可能适用于整个治疗疗程。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To investigate the interfractional variability of respiration-induced esophageal tumor motion using fiducial markers and four-dimensional cone-beam computed tomography (4D-CBCT) and assess if a 4D-CT is sufficient for predicting the motion during the treatment. MATERIALS AND METHODS: Twenty-four patients with 63 markers visible in the retrospectively reconstructed 4D-CBCTs were included. For each marker, we calculated the amplitude and trajectory of the respiration-induced motion. Possible time trends of the amplitude over the treatment course and the interfractional variability of amplitudes and trajectory shapes were assessed. Further, the amplitudes measured in the 4D-CT were compared to those in the 4D-CBCTs. RESULTS: The amplitude was largest in the cranial-caudal direction of the distal esophagus (mean: 7.1mm) and proximal stomach (mean: 7.8mm). No time trend was observed in the amplitude over the treatment course. The interfractional variability of amplitudes and trajectory shapes was limited (mean: ≤1.4mm). Moreover, small and insignificant deviation was found between the amplitudes quantified in the 4D-CT and in the 4D-CBCT (mean absolute difference: ≤1.0mm). CONCLUSIONS: The limited interfractional variability of amplitudes and trajectory shapes and small amplitude difference between 4D-CT-based and 4D-CBCT-based measurements imply that a single 4D-CT would be sufficient for predicting the respiration-induced esophageal tumor motion during the treatment course.
引用
- Jin P, Hulshof MCCM, van Wieringen N, et al. Interfractional variability of respiration-induced esophageal tumor motion quantified using fiducial markers and four-dimensional cone-beam computed tomography. Radiother Oncol. 2017. PMID: 28579281. doi:10.1016/j.radonc.2017.05.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。