文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

中危前列腺癌在线自适应放疗精囊边界研究

Exploring the Margin Recipe for Online Adaptive Radiation Therapy for Intermediate-Risk Prostate Cancer: An Intrafractional Seminal Vesicles Motion Analysis.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2017-02-24

PURPOSE: To provide a benchmark for seminal vesicle (SV) margin selection to account for intrafractional motion and to investigate the effectiveness of 2 motion surrogates in predicting intrafractional SV coverage. METHODS AND MATERIALS: Fifteen prostate patients were studied.…

要点

  • 5mm各向同性边界是减轻精囊分次内运动的最低要求。
  • 质心和轮廓边界均可预测精囊欠量,行动阈值分别为4.5mm和7.0mm。
  • 基于质心或轮廓边界的传统边界公式低估了所需边界。

核心结论

  • 精囊5mm各向同性边界是减轻分次内运动的最低要求。
  • 质心和轮廓边界均可作为精囊欠量的可接受预测指标。
  • 基于质心或轮廓边界的传统边界公式会低估所需边界。

研究设计与样本

  • 每对锥形束CT基于前列腺基准标记配准。
  • 治疗前精囊分别外扩1、2、3、4、5、8mm各向同性边界形成计划靶区,以治疗后精囊确定分次内覆盖的真实标准。

主要发现

  • 1、2、3、4、5、8mm边界分别使9%、53%、73%、86%、95%、97%的分次达到95%治疗后精囊覆盖率。
  • 5mm边界在超过90%的分次中提供95%分次内精囊覆盖率。
  • 质心与轮廓边界在左右、前后、头脚方向的相关性分别为弱、中等、强。

关键数值与推荐

  • 指数拟合得出质心和轮廓边界的欠量阈值分别为4.5mm和7.0mm。
  • Van Herk边界公式基于质心推荐左右、前后、头脚方向边界为0、0.5、0.8mm。
  • Van Herk边界公式基于轮廓边界推荐左右、前后、头脚方向边界为1.2、3.9、2.5mm。

临床怎么用

  • 在线自适应放疗中精囊边界选择可参考5mm各向同性边界作为最低要求。
  • 质心4.5mm和轮廓边界7.0mm可作为预测精囊欠量的行动阈值。
  • 不应仅依据基于质心或轮廓边界的传统边界公式确定精囊边界。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To provide a benchmark for seminal vesicle (SV) margin selection to account for intrafractional motion and to investigate the effectiveness of 2 motion surrogates in predicting intrafractional SV coverage. METHODS AND MATERIALS: Fifteen prostate patients were studied. Each patient had 5 pairs (1 patient had 4 pairs) of pretreatment and posttreatment cone beam CTs (CBCTs). Each pair of CBCTs was registered on the basis of prostate fiducial markers. All pretreatment SVs were expanded with 1-, 2-, 3-, 4-, 5-, and 8-mm isotropic margins to form a series of planning target volumes, and their intrafractional coverage to the posttreatment SV determined the "ground truth" for exact coverage. Two motion surrogates, the center of mass (COM) and the border of contour, were evaluated by the use of Pearson product-moment correlation coefficient and exponential fitting for predicting SV underdosage. Action threshold of each surrogate was calculated. The margin for each surrogate was calculated according to a traditional margin recipe. RESULTS: Ninety-five percent posttreatment SV coverage was achieved in 9%, 53%, 73%, 86%, 95%, and 97% of fractions with 1-, 2-, 3-, 4-, 5-, and 8-mm margins, respectively. The 5-mm margins provided 95% intrafractional SV coverage in over 90% of fractions. The correlation between the COM and border was weak, moderate, and strong in the left-right (L-R), anterior-posterior (A-P), and superior-inferior (S-I) directions, respectively. Exponential fitting gave the underdosage threshold of 4.5 and 7.0 mm for the COM and border. The Van Herk margin recipe recommended 0-, 0.5-, and 0.8-mm margins in the L-R, A-P, and S-I directions based on the COM, and 1.2-, 3.9-, and 2.5-mm margins based on the border. CONCLUSIONS: Five-millimeter isotropic margins for the SV constitute the minimum required to mitigate the intrafractional motion. Both the COM and the border are acceptable predictors for SV underdosage with 4.5- and 7.0-mm action threshold. Traditional margin based on the COM or border underestimates the margin.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Sheng Y, Li T, Lee WR, et al. Exploring the Margin Recipe for Online Adaptive Radiation Therapy for Intermediate-Risk Prostate Cancer: An Intrafractional Seminal Vesicles Motion Analysis. Int J Radiat Oncol Biol Phys. 2017. PMID: 28463167. doi:10.1016/j.ijrobp.2017.02.089

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。