文献速递胸部肿瘤放疗放疗物理与技术

肺肿瘤立体定向消融放疗后肺功能取决于受照肺区域通气功能

Pulmonary function after lung tumor stereotactic ablative radiotherapy depends on regional ventilation within irradiated lung.
PubMed 文献 · Radiother Oncol · 2017-04-28

该回顾性研究纳入27例接受肺肿瘤立体定向消融放疗(SABR)的患者,基于4-D CT定义通气比值VR20BED3(20Gy生物等效剂量等剂量体积内平均通气与全肺平均通气之比)。结果发现VR20BED3较高者FEV1下降更明显,而VR20BED3较低者FEV1改善,提示受照区域通气功能影响SABR后全局肺功能变化。

要点

  • VR20BED3较高(受照区域通气好)者SABR后FEV1下降更明显。
  • VR20BED3较低(受照区域通气差)者SABR后FEV1有所改善。
  • VR20BED3与SABR后PFT时间共同预测FEV1变化(R2=0.25,p=0.03)。

核心结论

  • SABR照射高通气功能肺区域后全局肺功能变差,照射低通气功能区域后全局肺功能改善。
  • VR20BED3若在更大研究中验证为SABR后PFT的预测因子,可用于个体化治疗计划以保留甚至改善肺功能。

研究设计与样本

  • 回顾性研究纳入2007至2014年在本机构接受SABR的27例患者,均无既往胸部放疗、有治疗前4-D CT且SABR前后PFT间隔<15个月。
  • VR20BED3定义为20Gy生物等效剂量(α/β=3Gy)等剂量体积内平均通气与全肺平均通气之比,通气基于形变配准的4-D CT吸气/呼气相逐体素体积变化的Jacobian计算。

主要发现

  • 多数患者按GOLD标准为中度至极重度COPD(n=19,70.1%)。
  • VR20BED3较高显著预测FEV1较基线下降更差(ΔFEV1/FEV1pre,p=0.04)。
  • VR20BED3>1(高区域通气)者n=7,ΔFEV1/FEV1pre中位数=-0.16(范围-0.230至-0.20)。
  • VR20BED3<1(低区域通气)者n=5,ΔFEV1/FEV1pre中位数=0.13(范围0.07至0.20)。
  • 多变量线性模型中VR20BED3增加和SABR后PFT时间延长预测ΔFEV1/FEV1pre下降(R2=0.25,p=0.03)。

临床怎么用

  • 治疗计划时可参考VR20BED3评估受照肺区域通气功能,以预判SABR后全局肺功能变化方向。
  • 对高通气功能区域照射可能需权衡肺功能下降风险,低通气区域照射可能不影响甚至改善肺功能。

局限性

  • 回顾性研究,样本量仅27例。
  • VR20BED3作为SABR后PFT预测因子尚需更大研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To determine if regional ventilation within irradiated lung volume predicts change in pulmonary function test (PFT) measurements after stereotactic ablative radiotherapy (SABR) of lung tumors. METHODS: We retrospectively identified 27 patients treated from 2007 to 2014 at our institution who received: (1) SABR without prior thoracic radiation; (2) pre-treatment 4-dimensional computed tomography (4-D CT) imaging; (3) pre- and post-SABR PFTs <15months from treatment. We defined the ventilation ratio (VR20BED3) as the quotient of mean ventilation (mean Jacobian-based per-voxel volume change on deformably registered inhale/exhale 4-D CT phases) within the 20Gy biologically effective dose (α/β=3Gy) isodose volume and that of the total lung volume (TLV). RESULTS: Most patients had moderate to very severe COPD by GOLD criteria (n=19, 70.1%). Higher VR20BED3 significantly predicted worse change in Forced Expiratory Volume/s normalized by baseline value (ΔFEV1/FEV1pre, p=0.04); n=7 had VR20BED3>1 (high regional ventilation) and worse ΔFEV1/FEV1pre (median=-0.16, range=-0.230 to -0.20). Five had VR20BED3<1 (low regional ventilation) and improved ΔFEV1/FEV1pre (median=0.13, range=0.07 to 0.20). In a multivariable linear model, increasing VR20BED3 and time to post-SABR PFT predicted decreasing ΔFEV1/FEV1pre (R2=0.25, p=0.03). CONCLUSIONS: After SABR to high versus low functioning lung regions, we found worsened or improved global pulmonary function, respectively. If pre-SABR VR20BED3 is validated as a predictor of eventual post-SABR PFT in larger studies, it may be used for individualized treatment planning to preserve or even improve pulmonary function after SABR.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Binkley MS, King MT, Shrager JB, et al. Pulmonary function after lung tumor stereotactic ablative radiotherapy depends on regional ventilation within irradiated lung. Radiother Oncol. 2017. PMID: 28460826. doi:10.1016/j.radonc.2017.03.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。