深吸气屏气预防左侧乳腺癌放疗早期心脏灌注缺陷的前瞻性研究
该前瞻性单臂单中心研究纳入20例接受左侧乳腺/胸壁切线放疗(含深吸气屏气DIBH及心脏挡块)的患者,通过放疗前及放疗后6个月SPECT评估心脏灌注与室壁运动。结果显示无患者出现放疗后灌注或室壁运动异常,提示DIBH联合适形心脏挡块可有效避免早期放疗相关心脏灌注缺陷。
要点
- DIBH联合心脏挡块用于左侧乳腺/胸壁切线放疗,未观察到早期心脏灌注缺陷。
- 研究纳入20例放疗前SPECT正常患者,放疗后6个月复查均无灌注或室壁运动异常。
- 心脏中位剂量94 cGy,中位V25Gy为0,提示心脏受量较低。
核心结论
- DIBH联合适形心脏挡块可有效避免左侧乳腺癌切线放疗患者的早期放疗相关心脏灌注缺陷。
研究设计与样本
- 前瞻性单中心单臂研究,纳入20例计划接受左侧乳腺/胸壁(±内乳淋巴结)切线放疗联合DIBH的患者。
- DIBH采用控制表面监测技术(AlignRT),放疗采用切线野加心脏挡块。
- 放疗前及放疗后6个月行SPECT扫描评估心脏灌注和室壁运动,采用累积SPECT静息总和评分量化左心室预定义节段灌注。
主要发现
- 共20例放疗前SPECT正常患者纳入分析,中位年龄56岁(范围39-72岁)。
- 7例(35%)患者同时接受左侧内乳链照射,5例(25%)接受锁骨上淋巴结追加照射。
- 心脏中位剂量为94 cGy(范围56-200 cGy),中位V25Gy为0(范围0-0.1)。
- 无患者出现放疗后灌注异常或室壁运动异常。
临床怎么用
- 对左侧乳腺癌接受切线放疗的患者,采用DIBH联合心脏挡块有助于降低早期心脏灌注缺陷风险。
局限性
- 研究为单中心单臂设计,样本量较小(20例),随访仅至放疗后6个月。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate early cardiac single photon computed tomography (SPECT) findings after left breast/chest wall postoperative radiation therapy (RT) in the setting of deep inspiration breath hold (DIBH). METHODS AND MATERIALS: We performed a prospective single-institution single-arm study of patients who were planned for tangential RT with DIBH to the left breast/chest wall (± internal mammary nodes). The DIBH was done by use of a controlled surface monitoring technique (AlignRT, Vision RT Ltd, London, UK). The RT was given with tangential fields and a heart block. Radiation-induced cardiac perfusion and wall motion changes were assessed by pre-RT and 6-month post-RT SPECT scans. A cumulative SPECT summed-rest score was used to quantify perfusion in predefined left ventricle segments. The incidence of wall motion abnormalities was assessed in each of these same segments. RESULTS: A total of 20 patients with normal pre-RT scans were studied; their median age was 56 years (range, 39-72 years). Seven (35%) patients also received irradiation to the left internal mammary chain, and 5 (25%) received an additional RT field to supraclavicular nodes. The median heart dose was 94 cGy (range, 56-200 cGy), and the median V25Gy was zero (range, 0-0.1). None of the patients had post-RT perfusion or wall motion abnormalities. CONCLUSIONS: Our results suggest that DIBH and conformal cardiac blocking for patients receiving tangential RT for left-sided breast cancer is an effective means to avoid early RT-associated cardiac perfusion defects.
引用
- Zagar TM, Kaidar-Person O, Tang X, et al. Utility of Deep Inspiration Breath Hold for Left-Sided Breast Radiation Therapy in Preventing Early Cardiac Perfusion Defects: A Prospective Study. Int J Radiat Oncol Biol Phys. 2016. PMID: 28333011. doi:10.1016/j.ijrobp.2016.12.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。