文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

基于放射组学的靶向放疗计划(Rad-TRaP):前列腺癌MRI治疗计划的计算框架

Radiomics based targeted radiotherapy planning (Rad-TRaP): a computational framework for prostate cancer treatment planning with MRI.
PubMed 文献 · Radiat Oncol · 2016-11-10

该研究提出Rad-TRaP框架,包含放射组学检测前列腺癌病灶、多模态可变形配准将MRI靶区映射至CT、以及基于放射组学的剂量计划生成三个模块。回顾性评估23例来自两机构患者,靶向局灶近距离放疗较全腺体均匀方案显著降低危及器官剂量并确保病灶处方剂量,外照射也呈相似趋势。

要点

  • 放射组学分类器可检测mpMRI上前列腺癌病灶并用于靶向计划。
  • 靶向局灶近距离放疗较全腺体均匀方案明显降低危及器官剂量。
  • 全腺体联合放射组学靶向推量较均匀方案仅轻微增加危及器官剂量。

核心结论

  • 基于放射组学的靶向局灶放疗计划框架可生成靶向治疗计划,在降低危及器官剂量同时提高病灶剂量。

研究设计与样本

  • 回顾性队列研究,纳入两个机构共23例患者研究,11例用于训练放射组学分类器,12例用于检测肿瘤区域并生成计划。

主要发现

  • 靶向局灶近距离放疗较全腺体均匀方案显著降低危及器官剂量,同时确保处方剂量递送至病灶。
  • 全腺体联合放射组学靶向推量较全腺体均匀方案仅轻微增加危及器官剂量。
  • 外照射中靶向局灶与全腺体联合靶向推量较全腺体均匀方案也呈现相似趋势。

临床怎么用

  • 可利用放射组学分类器在mpMRI上检测前列腺癌病灶,并通过可变形配准将靶区从MRI映射至CT用于近距离放疗和外照射计划设计。
  • 临床制定前列腺癌靶向局灶放疗计划时可参考该框架,以降低危及器官剂量并提高病灶剂量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Radiomics or computer - extracted texture features have been shown to achieve superior performance than multiparametric MRI (mpMRI) signal intensities alone in targeting prostate cancer (PCa) lesions. Radiomics along with deformable co-registration tools can be used to develop a framework to generate targeted focal radiotherapy treatment plans. METHODS: The Rad-TRaP framework comprises three distinct modules. Firstly, a module for radiomics based detection of PCa lesions on mpMRI via a feature enabled machine learning classifier. The second module comprises a multi-modal deformable co-registration scheme to map tissue, organ, and delineated target volumes from MRI onto CT. Finally, the third module involves generation of a radiomics based dose plan on MRI for brachytherapy and on CT for EBRT using the target delineations transferred from the MRI to the CT. RESULTS: Rad-TRaP framework was evaluated using a retrospective cohort of 23 patient studies from two different institutions. 11 patients from the first institution were used to train a radiomics classifier, which was used to detect tumor regions in 12 patients from the second institution. The ground truth cancer delineations for training the machine learning classifier were made by an experienced radiation oncologist using mpMRI, knowledge of biopsy location and radiology reports. The detected tumor regions were used to generate treatment plans for brachytherapy using mpMRI, and tumor regions mapped from MRI to CT to generate corresponding treatment plans for EBRT. For each of EBRT and brachytherapy, 3 dose plans were generated - whole gland homogeneous ([Formula: see text]) which is the current clinical standard, radiomics based focal ([Formula: see text]), and whole gland with a radiomics based focal boost ([Formula: see text]). Comparison of [Formula: see text] against conventional [Formula: see text] revealed that targeted focal brachytherapy would result in a marked reduction in dosage to the OARs while ensuring that the prescribed dose is delivered to the lesions. [Formula: see text] resulted in only a marginal increase in dosage to the OARs compared to [Formula: see text]. A similar trend was observed in case of EBRT with [Formula: see text] and [Formula: see text] compared to [Formula: see text]. CONCLUSIONS: A radiotherapy planning framework to generate targeted focal treatment plans has been presented. The focal treatment plans generated using the framework showed reduction in dosage to the organs at risk and a boosted dose delivered to the cancerous lesions.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Shiradkar R, Podder TK, Algohary A, et al. Radiomics based targeted radiotherapy planning (Rad-TRaP): a computational framework for prostate cancer treatment planning with MRI. Radiat Oncol. 2016. PMID: 27829431

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。