文献速递乳腺癌放疗放疗物理与技术

表面引导呼吸训练对乳腺癌放疗DIBH CT模拟可靠性的影响

How reliable is deep inspiration breath hold at CT simulation? Clinical impact of surface-guided breathing training in breast cancer radiotherapy.
PubMed 文献 · Radiat Oncol · 2026-09-04

该回顾性队列研究分析了115例接受DIBH CT模拟的乳腺癌患者,比较表面引导呼吸训练实施前后的DIBH可靠性与心脏剂量。训练后所有CT扫描均在预定屏气状态完成,平均PLVI增加约9%,屏气变异性降低约26%,心脏剂量显著降低,尤其在淋巴引流区照射亚组中部分心脏剂量指标降低达96%,同时保持靶区覆盖。

要点

  • 表面引导呼吸训练可消除CT模拟中不足或错误的DIBH采集。
  • 训练后平均PLVI增加约9%,屏气变异性降低约26%。
  • 胸骨运动与PLVI相关性最强,多区域表面监测内部相关性最高。

核心结论

  • 结合表面引导呼吸训练的CT模拟DIBH是可靠的,可避免错误呼吸状态下的计划CT并实现有临床意义的心脏剂量降低。

研究设计与样本

  • 回顾性队列研究,纳入115例接受DIBH CT模拟的乳腺癌患者,比较SGRT系统表面引导呼吸训练实施前后的DIBH表现与心脏剂量。

主要发现

  • 训练前观察到不足的DIBH CT(包括负PLVI病例),训练后所有CT扫描均在预定屏气状态采集,消除了不足的DIBH采集。
  • 训练后平均PLVI增加约9%,屏气变异性降低约26%。
  • 胸骨运动与PLVI相关性最强,多区域表面监测获得最高的内部相关性。
  • 心脏剂量显著降低,尤其在淋巴引流区照射亚组中部分心脏剂量指标降低达96%,同时保持靶区覆盖。

临床怎么用

  • 在乳腺癌DIBH CT模拟中实施表面引导呼吸训练,以避免错误呼吸状态下的计划CT并降低心脏剂量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Deep inspiration breath hold (DIBH) is widely used to reduce cardiac dose in left-sided breast radiotherapy. However, the reliability of DIBH at CT simulation, has not been systematically evaluated despite the importance of CT simulation as the basis for treatment planning. We investigated the clinical impact of surface-guided breathing training on DIBH reliability and cardiac dose sparing. METHODS: In this retrospective cohort study, 115 breast cancer patients undergoing DIBH CT simulation were analyzed before and after implementation of surface-guided breathing training using an SGRT system. DIBH performance was quantified by partial lung volume increase (PLVI) and breath-hold variability. Correlations between external surface motion and internal DIBH depth were assessed. Cardiac dose metrics were compared, with a subgroup analysis for patients receiving lymphatic drainage area (LDA) irradiation. RESULTS: Prior to training, insufficient DIBH CTs-including negative PLVI cases-were observed. After training implementation, all CT scans were acquired in intended breath-hold states, eliminating insufficient DIBH acquisitions. Mean PLVI increased by ~ 9%, and breath-hold variability decreased by ~ 26%. Sternum motion correlated most strongly with PLVI, with multiregion surface monitoring yielding the highest internal correlation. These improvements were reflected in significant reductions in cardiac dose, particularly in the LDA subgroup, with selected heart dose metrics reduced up to 96%, while maintaining target coverage. CONCLUSIONS: DIBH at CT simulation with surface-guided breathing training proves to be reliable. The training prevents planning CTs in wrong breathing states and thus enables clinically meaningful cardiac dose reduction in breast radiotherapy.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Dietrich L, Lackner N, Karius A, et al. How reliable is deep inspiration breath hold at CT simulation? Clinical impact of surface-guided breathing training in breast cancer radiotherapy. Radiat Oncol. 2026. PMID: 42698070. doi:10.1186/s13014-026-02920-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。