基于锥形束CT与深度学习的肺功能成像用于功能图像引导自适应放疗
研究开发三维门控注意力U-Net深度学习模型,从分次CBCT直接合成肺灌注功能图,在60例肺癌IMRT患者中与SPECT参考图像定量比较。结果显示体素级和功能区域一致性良好,基于CBCT功能图引导的计划较解剖计划显著降低高功能区平均剂量和V20。
要点
- 深度学习模型可从分次CBCT合成肺灌注图,与SPECT参考图一致性良好。
- CBCT功能图引导计划较解剖计划降低高功能区平均剂量6.97±4.22 Gy、V20降低13.54%±8.66%。
- 方法可行性获验证,但需更大队列研究进一步确认。
核心结论
- 基于CBCT的肺功能成像深度学习模型在功能引导计划中展示出可行性。
研究设计与样本
- 前瞻性收集60例接受调强放疗的肺癌患者,放疗前均行基线SPECT灌注扫描,其中16例放疗后行随访SPECT扫描。
- 开发三维门控注意力U-Net,在跳跃连接路径中整合门控注意力模块和三维可变形卷积,从CBCT直接合成灌注图。
主要发现
- CBCT合成功能图与SPECT参考图体素级Spearman相关系数R为0.68±0.09,结构相似性指数为0.75±0.09。
- 平均绝对误差为0.15±0.03,均方误差为0.04±0.02。
- 高功能区Dice相似系数为0.76±0.07,低功能区为0.85±0.05。
- CBCT功能图引导计划较解剖计划将肺高功能区平均剂量降低6.97±4.22 Gy,V20降低13.54%±8.66%。
- CBCT功能图引导计划靶区剂量均匀性指数为5.26±0.65,优于解剖计划。
临床怎么用
- 可利用分次CBCT合成肺灌注功能图,无需额外功能成像扫描即可支持功能引导自适应放疗计划设计。
局限性
- 研究样本量为60例,仅16例有放疗后随访SPECT,作者指出需更大队列研究进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Recent studies indicate that lung function can change significantly during the radiation therapy (RT) course. However, additional functional imaging scans are not part of routine RT workflow, limiting the use of functional avoidance for adaptive therapy. To bridge this gap, a deep learning model was developed to synthesize functional maps directly from fractional cone beam computed tomography (CBCT) images, enabling potential functional image guided adaptive RT. METHODS AND MATERIALS: Data were prospectively collected from 60 lung cancer patients who underwent intensity modulated RT. In addition to standard planning computed tomography and fractional CBCT scans, all patients received a baseline single-photon emission computed tomography (SPECT) perfusion scan before RT. A subset of 16 patients also underwent a follow-up SPECT scan after completing RT. A 3-dimensional Gated-Attention U-Net was developed to synthesize perfusion maps directly from CBCT images. To address the challenges of inherent CBCT noise and artifacts, the network architecture was augmented by integrating gated attention modules and 3-dimensional deformable convolutions within the skip-connection pathways. This design enhances multiscale feature fusion for more robust image synthesis. The synthesized perfusion images were quantitatively compared to the reference SPECT scans using cross-validation. Voxel-wise agreement was assessed using the Spearman rank correlation coefficient (R), structural similarity index measure, and mean squared error, while functional region agreement was evaluated using the Dice similarity coefficient. The potential clinical benefit was assessed through dosimetric evaluation. RESULTS: Quantitative analysis demonstrated strong agreement between the CBCT-based functional images and the ground-truth SPECT images, with an R of 0.68 ± 0.09, structural similarity index measure of 0.75 ± 0.09, mean absolute error of 0.15 ± 0.03, mean squared error of 0.04 ± 0.02, and Dice similarity coefficient values of 0.76 ± 0.07 and 0.85 ± 0.05 for high- and low-functional regions, respectively. Regarding dose sparing of the lung high-function region, the CBCT-based functional image guided plan significantly reduced the mean dose by 6.97 ± 4.22 Gy and V20 by 13.54% ± 8.66% compared to the anatomic plan, while achieving a better target dose homogeneity index of 5.26 ± 0.65. CONCLUSIONS: A CBCT-based lung function imaging method was developed using a deep learning model. The evaluation demonstrated its feasibility for functional guidance planning in functional image guided adaptive RT. A larger cohort study is warranted in the future.
引用
- Yu P, Pu Y, Xiong T, et al. Cone Beam Computed Tomography-Based Lung Function Imaging Using Deep Learning for Functional Image Guided Adaptative Radiation Therapy. Int J Radiat Oncol Biol Phys. 2026. PMID: 42679907. doi:10.1016/j.ijrobp.2026.08.054
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。