文献速递胸部肿瘤放疗放疗物理与技术

人工智能一键自动计划系统用于功能性肺避让放疗的临床实施与评估

Clinical Implementation and Evaluation of an Artificial Intelligence-Driven One-Click Automatic Planning System for Functional Lung Avoidance Radiation Therapy.
PubMed 文献 · Pract Radiat Oncol · 2026-09-16

本研究在RayStation治疗计划系统中临床实施并评估了人工智能驱动的功能性肺避让放疗自动计划系统(AP-FLART),该系统整合了基于剂量学评分的射束角度选择、多模态引导的剂量预测和功能引导的剂量模拟。使用33例接受SPECT通气或灌注成像并接受肺部放疗的肺癌患者进行测试,自动FLART计划较手动常规放疗计划显著降低高功能肺平均剂量15.1%,在FLART获益患者中降低≥2级放射性肺炎概率6.25个百分点(27%),87.9%的自动计划无需修改即可临床接受,计划时间从2-3小时缩短至约8分钟。

要点

  • AP-FLART一键自动计划将FLART计划时间从2-3小时缩短至约8分钟。
  • 自动FLART计划较高功能肺平均剂量较手动常规放疗降低15.1%。
  • 87.9%的自动FLART计划无需修改即可临床接受。

核心结论

  • 临床可行的一键式AP-FLART已成功实施并全面评估,在提高FLART计划效率和降低工作负荷方面具有前景。

研究设计与样本

  • 在RayStation治疗计划系统中临床实施AP-FLART系统,并使用33例接受SPECT通气或灌注成像及肺部放疗的肺癌患者进行测试和评估。

主要发现

  • 与手动常规放疗计划相比,自动FLART计划将高功能肺平均剂量降低15.1%。
  • 在FLART获益患者中,自动FLART计划将≥2级放射性肺炎概率降低6.25个百分点(27%),其他副作用概率相当。
  • 盲法评审显示87.9%的自动FLART计划无需修改即可临床接受,68.7%被评为与手动FLART计划相当(38.4%)或更优(30.3%)。
  • AP-FLART将手动FLART计划时间从2至3小时缩短至约8分钟。

临床怎么用

  • AP-FLART可一键自动生成功能性肺避让放疗计划,显著缩短计划时间并降低工作负荷。
  • 自动计划在多数情况下无需修改即可临床接受,且剂量学质量与手动FLART计划相当或更优。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study aimed to advance the clinical application of an artificial intelligence-driven automatic planning system for functional lung avoidance radiation therapy (AP-FLART) through clinical implementation and comprehensive evaluation. METHODS AND MATERIALS: AP-FLART integrates dosimetric score-based beam angle selection, multimodality-guided dose prediction, and function-guided dose mimicking. The system was enhanced and implemented within the clinical treatment planning system, RayStation. Clinical performance and potential benefits were assessed using a test data set comprising 33 patients with lung cancer who underwent Single-Photon Emission Computed Tomography (SPECT) ventilation or perfusion imaging and lung radiation therapy. Dosimetric metrics and normal tissue complication probabilities of automatic FLART plans were compared with manual conventional radiation therapy and FLART plans created by an experienced planner. Three clinicians conducted blinded reviews comparing the automatic and manual-FLART plans. RESULTS: Compared with manual conventional radiation therapy plans, automatic FLART plans significantly reduced the high-function lung mean dose by 15.1%. Among FLART-benefiting patients, automatic FLART plans reduced the probability of grade ≥2 radiation pneumonitis by 6.25 percentage points (27%), while maintaining comparable probabilities for other side effects. The estimated clinical benefits are similar to those of manual-FLART plans. Blinded reviews indicated that 87.9% of automatic FLART plans were clinically acceptable without modification, and 68.7% were rated as comparable (38.4%) or superior (30.3%) to manual-FLART plans. Furthermore, AP-FLART reduced planning time from 2 to 3 hours for manual-FLART planning to approximately 8 minutes. CONCLUSIONS: A clinically viable, one-click AP-FLART has been successfully implemented and comprehensively evaluated. AP-FLART shows considerable promise for improving the efficiency and reducing workload demands of FLART planning and advancing the broader clinical adoption of FLART.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Xiong T, Chen Z, Fan C, et al. Clinical Implementation and Evaluation of an Artificial Intelligence-Driven One-Click Automatic Planning System for Functional Lung Avoidance Radiation Therapy. Pract Radiat Oncol. 2026. PMID: 42749217. doi:10.1016/j.prro.2026.08.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。