整合CT与MRI的多模态无对比剂肺灌注成像用于增强肺功能评估
本研究前瞻性纳入21例肺癌患者,开发了整合CT与非增强MRI的双分支深度学习框架MCF-Q,用于无对比剂肺灌注重建,并与SPECT-Q对照。结果显示MCF-Q与SPECT-Q在体素水平R为0.7831±0.0821,在高功能区Dice为0.8396±0.0379,且MCF-Q引导的功能性肺回避放疗在高功能区获得更好剂量保护。
要点
- MCF-Q整合CT与非增强MRI,与SPECT-Q体素水平相关系数R为0.7831±0.0821。
- MCF-Q在高功能区Dice为0.8396±0.0379,低功能区为0.7680±0.0555。
- MCF-Q引导的FLART在高功能区剂量保护更优,全肺及危及器官剂量指标相当。
核心结论
- MCF-Q可从CT与非增强MRI实现多模态无对比剂肺灌注重建,与SPECT-Q一致性优于单模态方法,并提供可用于放疗计划的功能信息。
研究设计与样本
- 前瞻性分析纳入21例接受肺SPECT-Q、CT和1H MRI的肺癌患者,采用双分支深度学习架构融合CT与MRI特征重建肺灌注图,并进行七折交叉验证。
主要发现
- 体素水平MCF-Q与SPECT-Q的Spearman相关系数R为0.7831±0.0821。
- 功能相似性方面,MCF-Q在高功能区Dice为0.8396±0.0379,低功能区为0.7680±0.0555。
- MCF-Q所有指标较单模态肺功能成像方法均有显著改善。
- 剂量学分析中,MCF-Q引导的FLART在高功能区剂量保护更优,全肺及危及器官剂量指标相当。
关键数值与推荐
- MCF-Q与SPECT-Q体素水平相关性R为0.7831±0.0821。
- MCF-Q高功能区Dice为0.8396±0.0379。
- MCF-Q低功能区Dice为0.7680±0.0555。
临床怎么用
- 可利用常规采集的CT与非增强MRI生成无对比剂灌注图,指导功能性肺回避放疗计划设计。
局限性
- 样本量较小(21例),结论需在更大队列中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Anatomic image-driven lung function imaging methods have been explored for thoracic radiation therapy, but most contrast-free approaches rely on unimodal surrogates. This study aimed to develop a multimodal contrast-free pulmonary perfusion reconstruction framework multimodal contrast-free perfusion (MCF-Q) that integrates computed tomography (CT) and magnetic resonance imaging (MRI) to leverage complementary anatomic and functional information from routinely acquired CT and noncontrast MRI, improve agreement with single-photon emission CT perfusion (SPECT-Q), and explore its potential to support functional lung avoidance radiation therapy (FLART). METHODS AND MATERIALS: This prospective analysis included 21 patients with lung cancer who underwent pulmonary SPECT-Q, CT, and 1H MRI. MCF-Q adopted a dual-branch deep learning architecture to extract complementary features from CT and MRI and fuse them into pulmonary perfusion maps. Sevenfold cross-validation was performed to evaluate voxel-wise and function-wise agreement between MCF-Q and SPECT-Q, including Spearman's correlation coefficient (R) and the Dice similarity coefficient. The dosimetric analysis was also conducted by comparing a conventional radiation therapy plan with FLART plans guided by different perfusion maps. RESULTS: For voxel-wise assessment, the MCF-Q achieved an R value of 0.7831 ± 0.0821. For function-wise similarity, the MCF-Q gained the Dice similarity coefficient value of 0.8396 ± 0.0379 in high-functional regions, and 0.7680 ± 0.0555 in low-functional regions. All metrics calculated from MCF-Q showed significant improvement over single-modality-based lung function imaging methods. In dosimetric performance, the MCF-Q-guided FLART achieved better dose sparing in high-functional regions, while maintaining comparable whole-lung and organ-at-risk dose metrics. CONCLUSIONS: In this study, the proposed MCF-Q demonstrated the feasibility of multimodal perfusion reconstruction from CT and MRI, with improved agreement with SPECT-Q, and provided radiation therapy planning-relevant functional information that may facilitate functional lung avoidance strategies. These findings support the value of integrating routinely acquired CT and MRI for contrast-free, planning-relevant perfusion estimation, warranting validation in larger cohorts.
引用
- Hu D, Li B, Li H, et al. Multimodal Contrast-Free Pulmonary Perfusion Imaging by Integrating Computed Tomography and Magnetic Resonance Imaging for Enhanced Lung Function Assessment. Int J Radiat Oncol Biol Phys. 2026. PMID: 42532439. doi:10.1016/j.ijrobp.2026.07.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。