单次叩击通气屏气成像与实施在肺部肿瘤立体定向消融放疗中的前瞻性临床试验初步观察
该前瞻性临床试验首次在人体中验证叩击通气屏气(PVB)用于肺部肿瘤立体定向消融放疗(SABR)的可行性与安全性,使确认性容积图像引导与放疗实施在同一辅助屏气内完成。4例患者均成功完成PVB-SABR,每分次从最终锥形束CT图像验证开始至SABR实施结束的平均PVB持续时间为6分56秒,平均实施时间为2分22秒,平均占空比为93.5%。
要点
- 4例肺部肿瘤患者均成功完成PVB-SABR,初步证实可行性与安全性。
- 确认性容积图像引导与SABR实施可在同一PVB屏气内完成,消除屏气重复性不确定度。
- 每分次平均PVB持续时间6分56秒,平均实施时间2分22秒,平均占空比93.5%。
核心结论
- 首次前瞻性试验初步观察表明,PVB-SABR可行,能在同一有效屏气内完成确认性容积成像与SABR实施,消除屏气间重复性不确定度。
研究设计与样本
- 前瞻性、机构审查委员会批准的研究,4例肺部肿瘤患者先接受PVB耐受性教育评估,随后接受PVB-SABR治疗。
主要发现
- 4例患者均成功完成PVB-SABR。
- 每分次从最终锥形束CT图像验证开始至SABR实施结束的平均PVB持续时间为6分56秒,在单次PVB内完成。
- 该时段内平均每分次实施时间为2分22秒,平均占空比为93.5%。
临床怎么用
- PVB技术可在同一辅助屏气内完成确认性容积图像引导与SABR实施,有望减少呼吸运动所致不确定性。
局限性
- 仅为4例患者的初步观察,样本量小,需进一步研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Tumor motion during respiration presents a challenge in delivering high-precision stereotactic ablative radiation therapy (SABR) for lung cancer. While inspiratory breath-hold techniques can minimize motion, they are often limited by the patients' ability to sustain prolonged breath-holds and the variability that comes with repeat breath-holds. We present the first-in-human demonstration of the feasibility and safety of percussive ventilation breath-hold (PVB) to eliminate the uncertainty of breath-hold reproducibility between confirmatory volumetric image guidance and delivery of lung tumor SABR by completing both within the same assisted breath-hold. Here, we report that 4 patients were successfully treated as initial observations from a prospective clinical trial of PVB-SABR. METHODS AND MATERIALS: Four patients with lung tumors were treated in a prospective, institutional review board-approved study in which they underwent an education and evaluation session to assess their tolerance for PVB, followed by treatment with PVB-SABR. RESULTS: All 4 patients successfully completed PVB-SABR. The mean PVB duration per fraction from the beginning of the final cone beam computed tomography image verification to the end of SABR delivery was 6 minutes 56 seconds in a single PVB. Within that time, the mean delivery time per fraction was 2 minutes 22 seconds and the mean duty cycle was 93.5%. CONCLUSIONS: These initial observations in a first prospective trial of PVB-SABR demonstrate the feasibility of PVB to enable completion of SABR delivery within the same effective breath-hold as confirmatory volumetric imaging, eliminating the uncertainty of interbreath-hold reproducibility.
引用
- Mai WX, Huang KZ, Kuo J, et al. Single Percussive Ventilation Breath-hold Imaging and Delivery in Lung Tumor Stereotactic Ablative Radiation Therapy: Initial Observations From a Prospective Clinical Trial. Int J Radiat Oncol Biol Phys. 2026. PMID: 42397316. doi:10.1016/j.ijrobp.2026.05.034
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。