双能CT低能虚拟单能图像在头颈肿瘤放疗靶区分割中的作用
本研究评估双能CT生成的40-60 keV虚拟单能图像(VMI)对头颈肿瘤勾画的影响,发现50 keV VMI的对比噪声比显著高于120 kVp图像(1.99 vs 0.54,P=6.5×10⁻⁷),将其加入标准计划CT使GTV平均增加2.0 cm³,且基于VMI的轮廓与MRI更一致。
要点
- 50 keV VMI较120 kVp图像显著提高肿瘤对比噪声比,受医师偏好。
- 加入50 keV VMI后GTV平均增加2.0 cm³,轮廓与MRI更一致。
- VMI辅助作用受解剖部位影响,颅底区域获益较小。
核心结论
- 低能双能CT虚拟单能图像(尤其50 keV)可改善头颈肿瘤可视化,使GTV较120 kVp图像增大,并与MRI肿瘤勾画具有一致性。
研究设计与样本
- 勾画研究:生成40-60 keV VMI,用对比噪声比(CNR)和医师定性偏好评估最佳可视化能量。
- 将50 keV VMI纳入16例头颈癌患者的勾画研究,6名医师依次基于120 kVp等效DECT、50 keV VMI和MRI调整PET来源的GTV。
- 采用Dice系数、Hausdorff距离、平均一致距离和轮廓体积评估医师间及医师内变异性,并测量肿瘤可见度、边缘锐利度和勾画信心等定性指标。
主要发现
- 50 keV VMI的CNR显著高于120 kVp(1.99 vs 0.54,P=6.5×10⁻⁷),且医师更倾向于用其勾画肿瘤。
- 在120 kVp图像基础上加入50 keV VMI后,GTV平均体积增加2.0 cm³。
- 基于VMI的轮廓与MRI所见更一致;MRI与50 keV VMI轮廓间的医师内变异性小于MRI与120 kVp轮廓间。
- 随着每套图像集的加入,医师间变异性保持不变或略有增加。
- VMI的效用受解剖部位影响,颅底区域观察到的效果较小。
临床怎么用
- 可将低能DECT VMI(尤其50 keV)整合入头颈放疗多模态计划流程,以优化靶区勾画准确性。
- 勾画时需注意VMI可能使GTV较常规120 kVp图像增大,应结合MRI确认边界。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Accurate segmentation of head and neck (HN) tumors on computed tomography (CT) is made more challenging by limited soft-tissue contrast. Dual-energy CT (DECT), through virtual monoenergetic images (VMIs), offers improved tumor visualization, yet its impact on tumor segmentation remains underexplored. This study evaluates the effect of low-energy VMIs on the delineation of HN tumors within a multimodal imaging framework. METHODS AND MATERIALS: VMIs were created at energies from 40 to 60 keV and were evaluated for optimal tumor visualization using contrast-to-noise ratio (CNR) metrics and qualitative physician preference assessments. The 50 keV VMI, identified as the optimal compromise between contrast and image quality, was incorporated into a contouring study involving 16 patients with HN cancers. Six physicians adjusted positron emission tomography-derived gross tumor volumes (GTVs) sequentially, incorporating the following images: 120 kVp-equivalent DECT (standard planning CT), 50 keV VMI CT, and magnetic resonance image (MRI). Inter- and intra-physician variability were assessed using Dice coefficients, Hausdorff distance, mean distance to agreement, and contour volume. Qualitative metrics, including tumor conspicuity, edge sharpness, and contouring confidence, were measured. RESULTS: The 50 keV VMI demonstrated significantly higher CNR compared with the 120 kVp (CNR_50 keV = 1.99 vs CNR_120 kVp = 0.54, P = 6.5 × 10⁻7) and was favored by physicians for tumor delineation. The addition of 50 keV VMIs to the 120 kVp image increased GTVs with a mean volume increase of 2.0 cm3. The VMI-based contours were more consistent with findings on MRI. Intra-physician variability was less between MRI and 50 keV VMI contours than between MRI and 120 kVp contours, whereas inter-physician variability remained unchanged or increased slightly with the addition of each image set. Anatomic site influenced VMI utility, with less impact observed at the base of the skull. CONCLUSIONS: Low-energy DECT VMIs, particularly at 50 keV, enhance HN tumor visualization and lead to larger GTVs when compared with 120 kVp images alone, demonstrating consistency with MRI tumor delineation. These findings support the integration of VMIs into multimodal radiation therapy planning workflows to optimize target delineation accuracy.
引用
- Miller JR, Lawless M, DiMaso-Myers L, et al. The Role of Low-Energy Virtual Monoenergetic Images Derived From Dual-Energy Computed Tomography in Tumor Segmentation for Head and Neck Radiation Therapy: A Contouring Study. Adv Radiat Oncol. 2026. PMID: 42382435. doi:10.1016/j.adro.2026.102089
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。