文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

双等中心磁共振引导放疗用于大靶区宫颈癌的临床实施

Clinical Implementation of Dual-Isocenter Magnetic Resonance-Guided Radiation Therapy for Large-Target Cervical Cancer: A Dosimetric and Workflow Analysis.
PubMed 文献 · Pract Radiat Oncol · 2026-05-09

本研究纳入24例晚期宫颈癌患者,在Elekta 1.5 T MR-Linac上按头脚方向靶区大小分为单等中心(SI)组10例和双等中心(DI)组14例。结果显示两组放疗后毒性反应无统计学显著差异(P > .05),DI组平均治疗时间2495秒,SI组1337秒。研究建立了DI放疗工作流程并证明其可行性。

要点

  • DI与SI放疗后毒性反应无统计学显著差异(P > .05)。
  • DI组平均治疗时间2495秒,SI组1337秒。
  • 研究建立了双等中心MR引导放疗工作流程并证明可行。

核心结论

  • 双等中心磁共振引导放疗在大靶区宫颈癌患者中可行,其毒性谱与单等中心方法相当。

主要发现

  • 24例患者中位年龄59岁(范围35-78岁),SI组10例,DI组14例。
  • 采用CTCAE v5.0系统评估皮肤、胃肠道、泌尿、体能状态及妇科相关毒性,两组放疗后毒性无统计学显著差异(P > .05)。
  • SI组平均治疗时间1337秒(约22分钟),DI组2495秒(约42分钟)。
  • 两组剂量学数据均已呈现。

临床怎么用

  • 对于头脚方向靶区较大的宫颈癌患者,可考虑采用双等中心MR-Linac放疗,但需注意治疗时间较长。
  • DI放疗 workflow 可作为Unity MR-Linac系统临床实施的参考基础。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to investigate the feasibility of dual-isocenter (DI) radiation therapy under magnetic resonance linear accelerator (MR-Linac) guidance for patients with advanced cervical cancer. METHODS AND MATERIALS: A total of 24 patients with cervical cancer treated with Elekta 1.5 T MR-Linac from September 2022 to December 2024 were enrolled. Patients were stratified into single-isocenter (SI) or DI radiation therapy groups based on craniocaudal tumor target size. Postradiation therapy toxicities (assessed up to February 2025), dosimetric data, and radiation treatment time were analyzed. RESULTS: Among the 24 patients (median age, 59 years; range, 35-78 years), 10 received SI radiation therapy and 14 received DI radiation therapy. Key findings includes the following: (1) using Common Terminology Criteria for Adverse Events, version 5.0, systematic evaluation of skin, gastrointestinal, urinary, performance status, and gynecologic-related toxicities revealed no statistically significant differences in postradiation therapy toxicities between the 2 groups (P > .05); (2) dosimetric data for both groups were presented; (3) the mean treatment time for SI radiation therapy was 1337 seconds (approximately 22 minutes), compared with 2495 seconds (approximately 42 minutes) for DI radiation therapy. CONCLUSIONS: This study established a workflow for DI radiation therapy and demonstrated its feasibility through comparable toxicity profiles between DI and SI approaches. In addition, the dosimetric data and mean treatment time for both techniques in patients with cervical cancer provide a clinical foundation for magnetic resonance-guided radiation therapy using the Unity MR-Linac system.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Han Y, Wang C, Wang X, et al. Clinical Implementation of Dual-Isocenter Magnetic Resonance-Guided Radiation Therapy for Large-Target Cervical Cancer: A Dosimetric and Workflow Analysis. Pract Radiat Oncol. 2026. PMID: 42114804. doi:10.1016/j.prro.2026.04.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。